Version 2.0 (04/2019) Online
Translation of the original operating manual
27 von 54
Assembly and installation
Connection
Conductor cross-section / Information
Inputs/Outputs
Fine-strand: 0,08 bis 0,5 mm
2
Fine-strand with end-splice: 0,25 bis 0,34 mm
2
Stripped length: 5 to 6 mm
Power supply
Fine-strand: H05 (07) V-K 1,5 mm
2
Optional with end-splice
Stripped length: 6 to 7 mm
Peer-to-peer connection
Commercially-available Cat-5 cable (network or Ethernet cable)
¾
Prepare wire ends in accordance with the recommendations of the contact manufacturer.
¾
Insert the input/output and sensor wires into the mating plug using the yellow tool (see „Inputs and outputs”,
page 30)
.
¾
Insert the power supply wires into the mating plug with the black spare tool.
¾
Insert the mating plug into the ZoneControl.
¾
Ensure that all of the ZoneControl are connected to a common ground.
¾
Adjust the SPEED A, SPEED B, SPEED C, EPA/BA and DIR DIP switches according to requirements (see
„Operation”, page 39).
¾
Adjust the PNP/NPN DIP switch according to the signal level being used (applies to sensors and inputs and
outputs).
¾
Insert the RollerDrive connector so that the “RD” label on the ZoneControl is visible and the label on the
connector faces the rear (and is therefore not visible).
¾
Insert the plug of the PTP connection. When the ZoneControl is in the start zone and end zone, one PTP
connection remains free. There is no need for an end resistor.