Interroll Module belt conveyor SH 1100
Maintenance and repair
Version 1.0 (06/2022) en
Translation of original operating instructions
53
Removing/installing
contact guard and covers
at center drive station
2
3
4
5
4
3
6
1
3
4
5
Contact guard and covers at center drive station
1
Drive station
4
Washer
2
Contact guard
5
Captive washer
3
Torx screw
6
Cover
Fasten screws with a tightening torque of 19 Nm.
After initial tightening, the captive washers undergo plastic deformation and remain in the screw
shaft.
Requirement:
R
The module is shut down.
4
Loosen screws (3) at the contact guard (2) on the belt infeed side and remove contact
guard (2) from the cover (6).
4
Loosen screws (3) at the two covers (6) on the right and left at the drive station (1) and
remove the covers (6).
4
After the maintenance work: Install covers (6) and contact guard (2) from below at the drive
station (1).
4
To do so, guide three screws (3) with washers (4) in each case for both covers on the right
and left from the inside through the C-profile and fasten them.
4
Fasten contact guard (2) with two screws (3) and washers (4) each on the right and left at the
cover on the belt infeed side.