Interroll Module belt conveyor SH 1100
Maintenance and repair
Version 1.0 (06/2022) en
Translation of original operating instructions
69
Replacing sliding guides
Replacing the sliding guides requires removing the fastening profiles. The plastic fasteners hold
the sliding guides on the fastening profiles in position.
2
3
4
1
4
5
6
2
7
7
4
1
Side frame
5
Plastic fastener
2
Outside sliding guide
6
Torx screw
3
Guide rail
7
Fastening profile
4
Inside sliding guide (U-profile)
DANGER
Danger to life from electrocution and crushing
Installation and maintenance tasks on 400-V conveyor systems while they are in operation can
cause life-threatening electrocution and serious crushing.
4
Power down the entire conveyor module and ensure that it cannot be started accidentally.
Fasten screws with a tightening torque of 3.5 Nm.