User Manual of Digital Video Recorder
183
2)
If not, please contact the engineer from our company to do the further process.
The status of the added IPC displays as “Disconnected” when it is connected through the protocol of our
company. Select “Menu>Camera>Camera>IP Camera” to get the camera status.
Possible Reasons
a)
Network failure, and the DVR and IPC lost connections.
b)
The configured parameters are incorrect when adding the IPC.
c)
Insufficient bandwidth.
Steps
1.
Verify the configuration parameters are correct.
1)
Select “Menu>Camera>Camera>IP Camera”.
2)
Verify the following parameters are the same with those of the connected IP devices, including IP
address, protocol, management port, user name and password.
2.
Verify the whether the bandwidth is enough.
1)
Select “Menu >Maintenance > Net Detect > Network Stat.”.
2)
Check the usage of the access bandwidth, and see if the total bandwidth has reached its limit.
3.
Check if the fault is solved by the step 1 to step 3.
If it is solved, finish the process.
If not, please contact the engineer from our company to do the further process.
The IPC frequently goes online and offline and the status of it displays as “Disconnected”.
Possible Reasons
a)
The IPC and the HDVR versions are not compatible.
b)
Unstable power supply of IPC.
c)
Unstable network between IPC and HDVR.
d)
Limited flow by the switch connected with IPC and HDVR.
Steps
1.
Verify the IPC and the HDVR versions are compatible.
1)
Enter the IPC Management interface “Menu > Camera > Camera>IP Camera”, and view the firmware
version of connected IPC.
2)
Enter the System Info interface “Menu>Maintenance>System Info>Device Info”, and view the
firmware version of HDVR.
2.
Verify power supply of IPC is stable.
1)
Verify the power indicator is normal.
2)
When the IPC is offline, please try the ping command on PC to check if the PC connects with the IPC.
3.
Verify the switch is not flow control.
Check the brand, model of the switch connecting IPC and HDVR, and contact with the manufacturer of
the switch to check if it has the function of flow control. If so, please turn it down.
4.
Check if the fault is solved by the step 1 to step 4.
If it is solved, finish the process.
If not, please contact the engineer from our company to do the further process.
When there is no monitor connected to the HDVR and you add the IPC via web browser, the IPC status
Summary of Contents for I7-H0704/08/16Vh
Page 1: ...Digital Video Recorder User Manual...
Page 12: ...User Manual of Digital Video Recorder 11 Chapter 1 Introduction...
Page 21: ...User Manual of Digital Video Recorder 20 Chapter 2 Getting Started...
Page 32: ...User Manual of Digital Video Recorder 31 Chapter 3 Live View...
Page 41: ...User Manual of Digital Video Recorder 40 Chapter 4 PTZ Controls...
Page 50: ...User Manual of Digital Video Recorder 49 Chapter 5 Recording Settings...
Page 70: ...User Manual of Digital Video Recorder 69 Chapter 6 Playback...
Page 88: ...User Manual of Digital Video Recorder 87 Chapter 7 Backup...
Page 102: ...User Manual of Digital Video Recorder 101 Chapter 8 Alarm Settings...
Page 105: ...User Manual of Digital Video Recorder 104 Figure 8 6 Copy Settings of Motion Detection...
Page 108: ...User Manual of Digital Video Recorder 107 Figure 8 11 Copy Settings of Alarm Input...
Page 117: ...User Manual of Digital Video Recorder 116 Chapter 9 Network Settings...
Page 138: ...User Manual of Digital Video Recorder 137 Chapter 10 HDD Management...
Page 153: ...User Manual of Digital Video Recorder 152 Chapter 11 Camera Settings...
Page 159: ...User Manual of Digital Video Recorder 158 Chapter 12 Device Management and Maintenance...
Page 170: ...User Manual of Digital Video Recorder 169 Chapter 13 Others...
Page 181: ...User Manual of Digital Video Recorder 180 Chapter 14 Appendix...