![International Thermal Research Hurricane Chinook Heating System Manual Download Page 15](http://html1.mh-extra.com/html/international-thermal-research/hurricane-chinook-heating-system/hurricane-chinook-heating-system_manual_2080021015.webp)
International Thermal Research
3-1
Installing the Exhaust System
3.1 Before You Begin
For efficient and safe operation of the Hurricane
®
Chinook Heating
System follow all recommendations for properly installing the exhaust.
Any deviations from these must be approved in advance by ITR.
Although the heater’s exhaust produces very low carbon monoxide
emissions, caution is still advised:
•
Do not operate the Hurricane
®
Chinook Heating System in an
enclosed area unless there is adequate ventilation.
•
This is a direct vent system. The combustion air must be drawn
directly from the outside, without coming in contact with air that
can infiltrate the living areas. See section 3.3.
Never place any exhaust parts close to combustible material or
through a combustible wall or ceiling without fireproof protection. The
exhaust can reach high temperatures.
3.2 Mounting Location
If you can’t meet the technical specifications for mounting the
exhaust, don’t use the Hurricane
®
Chinook Heating System. The
unit may perform poorly or become damaged if not installed
according to specifications.
Recommended Exhaust Outlet Locations
The following is recommended for a Yacht exhaust outlet location:
•
The exhaust outlet of the Hurricane
®
Chinook Heating System is
located on top of the heater at the back.
Section
3
!
DANGER