50
TruVision IP Compact PTZ Camera Configuration Manual
Trigger Alarm Output
Trigger external alarm outputs when an event occurs. Select
one of the options: Select Trigger Alarm Output, A->1, or
A->2.
Note:
This option is only supported by cameras that support
alarm output.
10. Click
Save
to save changes.
Region entrance detection
This function detects people, vehicles or other objects that enter a designated region
from outside the designated region. Certain actions can be configured to occur when
the alarm is triggered.
To set up region entrance detection:
1. From the menu toolbar, click
Camera Configuration > Alarm/Event Setup> Region
Entrance Detection
.
2. Select
Enable
to enable the function.
3. Select the region number to be configured.
4. Click
Draw Area
, and then draw a rectangle on the image as the designated region.
When you draw the rectangle, all lines should connect end-to-end to each other. Up
to four areas are supported. Click
Clear
to clear the areas you have drawn. The
designated region parameters can be set up separately.
Note:
The area can only be quadrilateral.
5. Set the sensitivity level.
The sensitivity value defines the size of the object that can trigger the alarm. When
the sensitivity is high, a small object can trigger the alarm. The range is between 1
and 100.
6. Select the detection target from All, Human, or Vehicle.