![Interlogix TruVision TVP-1101 Configuration Manual Download Page 42](http://html1.mh-extra.com/html/interlogix/truvision-tvp-1101/truvision-tvp-1101_configuration-manual_2076947042.webp)
40
TruVision IP PTZ Camera FW 5.1 Configuration Manual
seconds, the camera starts to record at 9:59:55. The pre- event time can be configured
as No Pre-event, 5 s, 10 s, 15 s, 20 s, 25 s, 30 s, or not limited.
Post-event time
The post-event time is set to stop recording after the scheduled time or the event. For
example, if an alarm triggered recording ends at 11:00, and the post-event time is set
as 5 seconds, the camera records until 11:00:05. The post-event time can be
configured as 5 s, 10 s, 30 s, 1 min, 2 min, 5 min, or 10 min.
To set up a recording schedule:
1. From the menu toolbar, click
Configuration
>
Storage
>
Record Schedule
.
2. Select the pre and post-event times.
3. Enable overwrite, if required.
4. Select the recording stream (main stream, substream, or third stream).
5.Click the
Enable Record Schedule
box to enable recording.
Note:
To disable recording, deselect the option.
6. Click
Edit
to edit the recording schedule. The following window appears:
7. Select whether the recording will be for the whole week (
All Day
recording) or for
specific days of the week.
If you have selected “All Day” (1), select one of the record types to record from the
drop-down list box:
•
Continuous
: This is continuous recording.
•
Motion detection:
The video is recorded when the motion is detected.
•
Alarm:
The video is recorded when the alarm is triggered via the external alarm
input.
•
Motion | Alarm:
The video is recorded when the external alarm is triggered or
the motion is detected.
•
Motion & Alarm:
The video is recorded when motion,
alarms, and
audio
exception detection
are triggered at the same time.