TruVision IP PTZ Camera FW 5.1 Configuration Manual
37
3. Click
Edit
to set the arming schedule for the alarm input. See “Motion detection
alarms” on page 33 for more information on scheduling.
4. Select the linkage method to be used for the alarm input. The options are:
Normal Linkage: Notify Alarm Recipient, Send Email, Upload Snapshot, Trigger
channel
Other Linkage: Trigger Alarm Output, PTZ Linking
For
Trigger Alarm Output
the options are: Select All, A->1, or A->2
For
PTZ Linkage
the options are: Preset No., Preset Tour No., or Shadow Tour No.,
and enter the desired number.
5. To copy the alarm setup to another alarm input, select one of the options shown
under
Copy to Alarm
.
6. Click
Save
to save changes.
To define an alarm output:
1. From the menu toolbar, click
Configuration
>
Events
>
Alarm Output
.
2. Select one alarm output channel from the
Alarm Output
drop-down list. You can
also set a name for the alarm output.
3. The delay time can be set to 5 s, 10 s, 30 s, 1 min, 2 min, 5 min, 10 min or Manual.
The delay time refers to the time duration that the alarm output remains in effect
after alarm occurs.
4. Click
Edit
to set the arming schedule for the alarm output. See “Motion detection
alarms” on page 33 for more information on scheduling.
5. To copy the alarm setup to another alarm input, select one of the options shown
under
Copy to Alarm
.
6. Click
Save
to save changes.
Exception alarms
You can set up the camera to notify you when irregular events occur and how you
should be notified. These exception alarms include:
• HDD Full:
All recording space of NAS is full.
• HDD Error:
Errors occurred while files were being written to the storage, no storage
or storage had failed to initialize.
• Network Disconnected:
Disconnected network cable.
• IP Address Conflicted:
Conflict in IP address setting.
•
Invalid Login
: Wrong user ID or password used to login to the cameras.
To define exception alarms:
1. From the menu toolbar, click
Configuration
>
Events
>
Exception
.