PITCH SLIDERS
(SECTION 1)
These sliders determine the default pitch value of each corresponding stage. Metropolix uses the
position of these sliders as a starting point for determining the actual pitch output by each stage on
each track.
On a GLOBAL level:
● Via the
SCALE
button, you can assign a scale type and root note to any quantized slider.
● Via the
SETUP
button, you can define which note represents the bottom of the slider (either a
“C” or the current scale’s root note).
On a per-TRACK level (accessed via the
TRACK MENU
), you can assign:
● The pitch range of the slider (from 1 octave bottom-to-top, to 4 octaves bottom-to-top)
● Whether the slider’s lowest pitch is at the bottom (normal) or at the top (inverted).
● An overall output transposition above or below the default pitch value (±60 semitones).
Metropolix Manual
15