Intel
®
Server System SR2520SA User’s Guide
41
Removing a SAS or SATA Hot-swap Hard Disk Drive
(SR2520SAX/SR2520SAXS and SR2520SAXR/
SR2520SAXSR)
1. Remove the front bezel if it is installed. For instructions, see
“Removing the Front
Bezel”
.
2. Press in on the green latch at the front of the hard drive carrier.
3. Pull out on the black lever to slide the carrier from the server system.
4. Remove the four screws that attach the hard drive to the drive carrier. Lift the drive
from the carrier. Store the drive in an anti-static bag.
5. If you are not installing a new drive, place the plastic retention device into the drive
carrier, using the four screws you removed from the hard drive.
6. Insert the screws that held the drive in the carrier into the screw locations on the
carrier for future use.
7. With the black lever in the fully open position, slide the drive carrier into the server
system. The green latch must be to the right. Do not push on the black lever until
the lever begins to close by itself.
Note: For proper airflow, the hard drive carrier must be replaced in the server system, even if no
hard drive is installed in it.
8. When the black lever begins to close by itself, push on it to lock the drive carrier
into place.
9. Install the server system cover. For instructions, see
“Installing the System Cover”
.
10. (Optional) Install the front bezel. For instructions, see
“Installing the Front Bezel”
.
11. Plug all peripheral devices and the AC power cable(s) into the server.
Installing and Removing a Fixed Hard Drive
(SR2520SAF/SR2520SAFR)
Up to six fixed SATA drives can be installed.
Note: The server system does not support all hard drives. See
“Server System References“
for
an Internet link to a list of supported hardware.
Installing a Fixed Hard Disk Drive (SR2520SAF/
SR2520SAFR)
1. Remove the server system cover.
Summary of Contents for SR2520SA
Page 3: ...Intel Server System SR2520SA User s Guide iii...
Page 4: ...iv Intel Server System SR2520SA User s Guide...
Page 12: ...xii Intel Server System SR2520SA User s Guide...
Page 18: ...xviii Intel Server System SR2520SA User s Guide...
Page 22: ...xxii Intel Server System SR2520SA User s Guide...
Page 42: ...20 Intel Server System SR2520SA User s Guide...
Page 92: ...70 Intel Server System SR2520SA User s Guide...
Page 106: ...84 Intel Server System SR2520SA User s Guide...
Page 118: ...96 Intel Server System SR2520SA User s Guide...
Page 140: ...118 Intel Server System SR2520SA User s Guide...
Page 164: ...142 Intel Server System SR2520SA User s Guide...