Intel
®
Server System SR2520SA User’s Guide
37
9. Raise the CPU load plate.
10. Remove the processor.
11. If installing a replacement processor, see
“Installing the Processor”
. Otherwise,
install the protective socket cover over the empty processor socket and reinstall the
system’s cover.
Installing and Removing a Hot-swap Hard Drive
(SR2520SAX/SR2520SAXS and SR2520SAXR/
SR2520SAXSR)
Up to six hot-swap SATA drives or SAS drives can be installed.
Cautions: If you install less than six drives or devices, the empty drive bays must be occupied by
carriers with baffles to maintain proper system cooling.
To avoid possible damage to your server system, do not use older style drive carriers.
Note: The server system does not support all hard drives. See
“Server System References“
for
an Internet link to a list of supported hardware.
Installing a SAS or SATA Hot-swap Hard Disk Drive
(SR2520SAX/SR2520SAXS and SR2520SAXR/
SR2520SAXSR)
1. Remove the front bezel if it is installed. For instructions, see
“Removing the Front
Bezel”
.
2. Open the green latch at the front of the hard drive carrier.
3. Pull out on the black lever and slide the carrier from the server system.
Summary of Contents for SR2520SA
Page 3: ...Intel Server System SR2520SA User s Guide iii...
Page 4: ...iv Intel Server System SR2520SA User s Guide...
Page 12: ...xii Intel Server System SR2520SA User s Guide...
Page 18: ...xviii Intel Server System SR2520SA User s Guide...
Page 22: ...xxii Intel Server System SR2520SA User s Guide...
Page 42: ...20 Intel Server System SR2520SA User s Guide...
Page 92: ...70 Intel Server System SR2520SA User s Guide...
Page 106: ...84 Intel Server System SR2520SA User s Guide...
Page 118: ...96 Intel Server System SR2520SA User s Guide...
Page 140: ...118 Intel Server System SR2520SA User s Guide...
Page 164: ...142 Intel Server System SR2520SA User s Guide...