Product Overview
Intel®
Server System SR1625UR TPS
6
Revision 1.5
Intel order number E47487-007
Table 2. Mixed Processor Configurations
Error
Severity
System Action
Processor family not
identical
Fatal
The BIOS detects the error condition and responds as follows:
Logs the error into the system event log (SEL).
Alerts the Integrated BMC of the configuration error with an IPMI
command.
Does not disable the processor.
Displays “0194: Processor family mismatch detected” message
in the error manager.
Halts the system.
Processor cache not
identical
Fatal
The BIOS detects the error condition and responds as follows:
Logs the error into the SEL.
Alerts the Integrated BMC of the configuration error with an IPMI
command.
Does not disable the processor.
Displays “0192: Cache size mismatch detected” message in the
error manager.
Halts the system.
Processor frequency (speed)
not identical
Major
The BIOS detects the error condition and responds as follows:
Adjusts all processor frequencies to lowest common
denominator.
Continues to boot the system successfully.
If the frequencies for all processors cannot be adjusted to be the
same, then the BIOS:
Logs the error into the SEL.
Displays “0197: Processor speeds mismatched” message in the
error manager.
Halts the system.
Processor microcode
missing
Fatal
The BIOS detects the error condition and responds as follows:
Logs the error into the SEL.
Alerts the Integrated BMC of the configuration error with an IPMI
command.
Does not disable processor.
Displays “816x: Processor 0x unable to apply microcode update”
message in the error manager.
Pauses the system for user intervention.
Processor Intel
®
QuickPath
Interconnect speeds not
identical
Halt
The BIOS detects the error condition and responds as follows:
Logs the error into the system event log (SEL).
Alerts the Integrated BMC of the configuration error with an IPMI
command.
Does not disable the processor.
Displays “0195: Processor Front Side Bus speed mismatch
detected” message in the error manager.
Halts the system.