Intel
®
Server System SR1520ML User’s Guide
65
7. Close the server chassis.
8. Reconnect the AC power and power up the server.
Clearing the CMOS
If you are not able to access the BIOS setup screens, the CMOS Clear jumper can be used
to reset the configuration RAM.
1. Power down the system and disconnect the AC power.
2. Open the server.
3. Move the J1A3 CMOS Clear jumper from the normal operation position, CMOS
Clear by BMC, at pins 1 and 2 to the CMOS Clear Force Erase position, covering
pins 2 and 3 as indicated in the following diagram.
Figure 48. CMOS Clear Jumper in Clear CMOS Position
4. Reconnect the AC power, power up the system.
5. When the system begins beeping, power it down and disconnect the AC power.
AF002606
3
2
Default
CLEAR
CMOS
J1A3
CMOS
Clear
Summary of Contents for SR1520ML - Server System - 0 MB RAM