Intel
®
Server System SR1520ML User’s Guide
37
5. Gradually and equally tighten each captive screw in the same order until each is
firmly tightened.
Figure 29. Installing the Heat Sink
6. Install the processor air duct. For instructions, see
“Installing the Processor Air
Duct” on page 29
.
7. Install the server system cover. For instructions, see
“Installing the Server System
Cover”
.
Replacing the Power Supply
Caution: The power supply is NOT hot swappable. Before removing or replacing the power supply,
you must first take the server out of service, turn off all peripheral devices connected to
the system, turn off the system by pressing the power button, and unplug the AC power
cord from the system or wall outlet.
The power supply can be replaced if it fails or if one of the fans that is integrated into it
fails. To replace the power supply, use the following instructions.
1. Observe the safety and ESD precautions at the beginning of this book. See
“Safety
Information” on page iii
.
2. Power down the server and unplug all peripheral devices and the AC power cable.
AF002517
3
1
2
4
A
B
Summary of Contents for SR1520ML - Server System - 0 MB RAM
Page 6: ...vi Intel Server System SR1520ML User s Guide...
Page 12: ...xii Intel Server System SR1520ML User s Guide...
Page 14: ...xiv Intel Server System SR1520ML User s Guide...
Page 62: ...42 Intel Server System SR1520ML User s Guide Figure 34 Removing Bracket and Fans AF002507 B A...
Page 78: ...58 Intel Server System SR1520ML User s Guide...
Page 90: ...70 Intel Server System SR1520ML User s Guide...
Page 96: ...76 Intel Server System SR1520ML User s Guide...
Page 108: ...88 Intel Server System SR1520ML User s Guide...
Page 118: ...98 Intel Server System SR1520ML User s Guide...
Page 122: ...102 Intel Server System SR1520ML User s Guide...
Page 126: ...106 Intel Server System SR1520ML User s Guide...
Page 150: ...130 Intel Server System SR1520ML User s Guide...