Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family
11
2.3.2
Installing the Air Duct
1.
Align the front end of the air duct with the hinges on both sides of the fan bracket (see letter
A
).
2.
Rotate the air duct (see letter
B
) and lower down the rear end of the air duct until the left and right side
buttons are firmly in place.
Figure 14.
Installing the Air Duct
2.4
Removing and Installing the Processor
The heatsink has thermal interface material (TIM) on the underside of it. Use caution so that you do not
damage the thermal interface material. Use gloves to avoid sharp edges.
2.4.1
Removing the Processor Heatsink
The heatsink is attached to the server board or processor socket with captive fasteners. Using a #2 Phillips*
screwdriver, loosen the four screws located on the heatsink corners in a diagonal manner using the following
procedure:
1.
Using a #2 Phillips* screwdriver, start with screw 1 and loosen it by giving it two rotations and stop (see
letter
A
). (
IMPORTANT:
Do not fully loosen.)
2.
Proceed to screw 2 and loosen it by giving it two rotations and stop (see letter
B
). Similarly, loosen
screws 3 and 4. Repeat steps A and B by giving each screw two rotations each time until all screws are
loosened.
3.
Lift the heatsink straight up (see letter
C
).