The following table defines the system level operating and non-operating environmental limits.
Table 4.
System Environmental Limits Summary
Parameter
Limits
Operating Temperature
+10°C to +35°C with the maximum rate of change not to
exceed 10°C per hour
Non-Operating Temperature
-40°C to +70°C
Non-Operating Humidity
90%, non-condensing at 35°C
Acoustic noise
Sound power: 7.0BA with hard disk drive stress only at room
ambient temperature (23 +/- 2°C)
Shock, operating
Half sine,
peak, 11 mSec
Shock, unpackaged
, velocity change 205 inches/second (80
lbs to < 100 lbs)
Vibration, unpackaged
5 Hz to 500 Hz, 2.20 g RMS random
Shock and vibration, packaged
ISTA (International Safe Transit Association) Test Procedure 3A
ESD
+/-12 KV except I/O port +/- 8 KV per Intel
®
Environmental Test
Specification
System Cooling Requirement in BTU/Hr
1600 Watt Max – 5459 BTU/hour
2130 Watt Max – 7268 BTU/hour
Disclaimer Note:
Intel ensures the unpackaged server board and system meet the shock requirement
mentioned above through its own chassis development and system configuration. It is the responsibility of
the system integrator to determine the proper shock level of the board and system if the system integrator
chooses different system configuration or different chassis. Intel Corporation cannot be held responsible, if
components fail or the server board does not operate correctly when used outside any of its published
operating or non-operating limits.