MLR 3G 2.0
Functions
by a VCom authentication during the existing connection. This setting is ig-
nored if IPT is used.
In order to specify that an
ATD dialling command triggers an outgoing con-
nection
, select in the "Outgoing connection" section the radio button "trig-
gered by dialling command ATD". Then, the serial interface will be operated in
AT command mode and a connection must be initiated by an ATD command.
The Serial Ethernet Gateway expects the dialling command ATD via the serial
interface with the destination as IP address or domain name, followed by the
TCP port (e.g.: ATD192.168.1.1:1234 or ATD"name.company.com":1234. When
using IPT, only the IPT number is specified here (e.g.: "ATD12345").
In order to specify that a
character on the serial interface triggers an outgoing
connection
, select in the "Outgoing connection" section the radio button
"triggered by serial character". Then, a connection will be established as soon
as a WAN connection is established. A destination must be specified in this
operation mode. Enter the IP address or the domain name of the target into
the "IP address or domain name" field as well as the port into the "Port" field.
Alternatively, enter for an IPT connection the IPT number into the "IPT dial
number" field. A secondary target can be entered optionally, to which a con-
nection will be established if the primary target is not available. If the connec-
tion set-up fails, a new connection set-up cannot be performed before
5 minutes have expired.
In order to specify a
set-up of an outgoing connection by an active WAN con-
nection
, select in the "Outgoing connection" section the radio button "trig-
gered by active WAN connection". Then, a connection will be established as
soon as a WAN connection is established. A destination must be specified in
this operation mode. Enter the IP address or the domain name of the target
into the "IP address or domain name" field as well as the port into the "Port"
field. Alternatively, enter for an IPT connection the IPT number into the "IPT
dial number" field. A secondary target can be entered optionally, to which a
connection will be established if the primary target is not available.
In order to
establish a connection in leased line mode
, it is also necessary, to
enter the IP address or the domain name of the target as well as the port or
the IPT dial number. A secondary destination can be entered optionally.
In order to use
authentication via TCP or UDP
at an INSYS VCom for outgoing
connections, select in the "VCom authentication" section for "outgoing" either
the radio button "UDP" or "TCP". This authentication will also be used in
leased line mode. This setting is ignored if IPT is used.
Save your settings
by clicking "OK". The serial Ethernet gateway will be re-
started with this. Existing serial Ethernet gateway connections will be termi-
nated.
65