INSYS GPRS/EDGE 5.0 serial
Functions
71
6.8
Remote Configuration
During a CSD or “TCP transparent” data connection, the INSYS
GPRS/EDGE 5.0 serial can be switched to remote command mode
by entering the escape sequence via the data connection from
the remote terminal.
Note: After the 4 escape characters were entered at the local de-
vice (1 second pause before and after the entry, no re-
turn -
<CR>
-), the remote configuration at the remote
terminal is activated. The data connection is main-
tained in the background. The 4 escape characters must
be entered within 1 second.
If this was configured, the configuration password is queried be-
fore the switching to the remote command mode occurs.
Note: See also Chapter
6.1.1
- Password Protection
After the escape sequence is detected, the prompt for entering
the password appears.
If no valid password is entered within 30 seconds (attention:
complete the entry with line end character), the configuration
mode will be exited with the following message
A valid password is acknowledged with
OK
; now the
AT
com-
mands released for remote configuration can be entered.
Terminate configuration
Note:
Due to the sometimes long packet run times for TCP
connections, the escape character **** must be sent in
one
TCP packet. Otherwise the pauses between the in-
dividual characters get too large and the reception of
the sequence is terminated.
<pause>
****
<pause>
CONFIG
PASSWORD:
ERROR
OK
AT**EXIT
6.9
Firmware Update
The firmware of the
µ
controller can be loaded locally (via the serial
interface), and remote (CSD or "TCP transparent" connection).
Before the firmware is updated, hardware handshake must
always be activated ((INSYS GPRS/EDGE 5.0 serial and re-
mote terminal).
The process is started. The device prepares itself for receiving the
new firmware.
AT**FLASH
Send *.HEX
file now
Summary of Contents for EDGE 5.0 Series
Page 1: ...Manual INSYS GPRS EDGE 5 0 serial Sep 10...
Page 2: ......
Page 63: ...INSYS GPRS EDGE 5 0 serial Functions 63...
Page 67: ...INSYS GPRS EDGE 5 0 serial Functions 67 Configuration of the first device...
Page 68: ...Functions INSYS GPRS EDGE 5 0 serial 68 Configuration of the second device...
Page 103: ...INSYS GPRS EDGE 5 0 serial Declaration of Conformity 103 15 Declaration of Conformity...
Page 104: ...Declaration of Conformity INSYS GPRS EDGE 5 0 serial 104...
Page 107: ......