8.8.1.2
Data Logger User Data
A data logger message has the following setup:
Device
ID
4
byte
2 x 8 bit for the digital inputs
2 byte
4 x 16 bit for the analogue inputs
8 byte
Checksum
1 byte
Total
15 byte
8.8.1.3
User Data Acknowledge of the Control Center
As an option, the data logger/control center software can be configured so that
for a data logger message an acknowledging message of the control center (user
data acknowledge) is sent.
Set-up:
Command
(e.g.
ACK) 1
byte
Checksum
1 byte
Total
2 byte
8.8.2
General Data Amount
For GPRS, such as for all IP-based transmission methods, the user data of the ap-
plication are packed into a TCP/IP message and sent to the remote terminal
(PUSH); the TCP/IP stack of the remote terminal (e.g. Windows) must acknowledge
each received TCP/IP message.
With GPRS, all data accumulated by the user from the IP level (incoming and out-
going) are calculated.
8.8.2.1
Transmission of User Data without User Data Acknowledge of the Remote Ter-
minal
Total: 95 byte
Applikation
/
GPRS Modem
Leitstelle
Nutzdaten: 15
TCP/IP PUSH: 40
Nutzdaten:
0
TCP/IP ACK
: 40
Summary of Contents for EDGE 5.0 Series
Page 1: ...Manual INSYS GPRS EDGE 5 0 serial Sep 10...
Page 2: ......
Page 63: ...INSYS GPRS EDGE 5 0 serial Functions 63...
Page 67: ...INSYS GPRS EDGE 5 0 serial Functions 67 Configuration of the first device...
Page 68: ...Functions INSYS GPRS EDGE 5 0 serial 68 Configuration of the second device...
Page 103: ...INSYS GPRS EDGE 5 0 serial Declaration of Conformity 103 15 Declaration of Conformity...
Page 104: ...Declaration of Conformity INSYS GPRS EDGE 5 0 serial 104...
Page 107: ......