11 Battery Replacement
If the server no longer automatically displays the correct date and time, you may need to
replace the battery that provides power to the real-time clock.
WARNING:
The computer contains an internal lithium manganese dioxide, a vanadium
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is
not properly handled. To reduce the risk of personal injury:
•
Do not attempt to recharge the battery.
•
Do not expose the battery to temperatures higher than 60°C (140°F).
•
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
•
Replace only with the spare designated for this product.
To remove the component:
1.
Power down the server.
2.
Extend the server from the rack.
3.
Remove the access panel.
4.
Remove the full-length expansion board retainer if any full-length expansion boards are
installed.
5.
Remove the PCI riser cage.
6.
Remove the air baffle.
7.
Remove the battery.