BMC Settings
131
directly erase and overwrite flash with new image without Firmware Integrity Checking. All
configuration will be erased. This is an inband mode, users should accept user permission.
9.23.1.1 Firmware Integrity Checking
Each firmware image has a MD5 code calculated by MD5 tool (Hash.exe). Before firmware
update, users must check integrity using MD5 tool to make sure the firmware image file is
the correct one.
9.23.1.2 Dual image
Dual image means BMC supporting two images in flash, when active image cannot boot,
BMC will try another image to boot.
9.23.1.3 WEB Update
BMC firmware update is supported via the Management Web GUI.
●
Support hardware watchdog, please refer to “Hardware watchdog” in section “BMC Self
Recovery”.
When updating BMC firmware, users can specify which image to update.
●
Image-1
●
Image-2
●
Inactive image
●
Both images (Default)
Configurations can be preserved separately. Please refer to section “Restore Factory
Default”.
Note:
The firmware upgrade process is a crucial operation. Make sure that the chances of a
power or connectivity loss are minimal when performing this operation.
Once you enter into Update Mode and choose to cancel the firmware flash operation, BMC
must be reset. This means that you must close the Internet browser and log back onto the
BMC before you can perform any other types of operations.
It defaults to boot the higher version of the two images. You can change the value from the
Web GUI.
Step 1
Go to “Administration->Dual Image Update” page, and select image to update. It defaults
Summary of Contents for NF8480M5
Page 1: ...Inspur Server User Manual NF8480M5 ...
Page 66: ...60 information 3 2 Create RAID Volume Enter this menu interface as shown below ...
Page 92: ...86 sensor Figure 6 Sensor fru Figure 7 Fru chassis Figure 8 Chassis user Figure 9 User ...
Page 93: ...BMC Settings 87 mc Figure 10 MC fan Figure 11 Fan psu Figure 12 Psu id Figure 13 Id diagnose ...
Page 143: ...BMC Settings 137 Figure 56 SOL Setting in BIOS Figure 57 Default Serial Setting ...