BMC Settings
101
9.8.5 PSU
Table 25 PSU Health State Monitored
State
Level
Related Model
Present
Info
SDR/SEL/ Blackbox
Power Supply Failure
Critical
SDR/SEL/ Blackbox
Predictive Failure
Warning
SDR/SEL/ Blackbox
Power Supply AC lost
Critical
SDR/SEL/ Blackbox
9.9 Logs
Logs provide the history record of main devices state changes, used for fault diagnostic.
9.9.1 System Event Log
BMC provides the ability to record IPMI sensor based event history. System event log
outputs following items and user can get the sensor event information by WEB or IPMI
CMD.
●
Support up to 3639 items.
●
Support linear mode. When SEL is full, new log will be discarded.
●
Support cycle mode, default mode. When SEL is full, oldest log will be discarded.
●
When SEL is almost full (75%), then Almost full log will be recorded in SEL.
●
When SEL is full in linear mode, Full log will be recorded in SEL.
●
When SEL is clear, Clear log will be recorded in SEL.
●
Support exporting SEL by WEB or IPMI CMD.
●
Support informing event to remote client by SNMP Trap, Email Alert, Syslog.
Go to page “Logs -> System Event Log” in Web GUI, all sensor based logs are displayed, users
can filter events by event severity, time, or sensor.
Summary of Contents for NF8480M5
Page 1: ...Inspur Server User Manual NF8480M5 ...
Page 66: ...60 information 3 2 Create RAID Volume Enter this menu interface as shown below ...
Page 92: ...86 sensor Figure 6 Sensor fru Figure 7 Fru chassis Figure 8 Chassis user Figure 9 User ...
Page 93: ...BMC Settings 87 mc Figure 10 MC fan Figure 11 Fan psu Figure 12 Psu id Figure 13 Id diagnose ...
Page 143: ...BMC Settings 137 Figure 56 SOL Setting in BIOS Figure 57 Default Serial Setting ...