Ver0.1
Page
18
of
53
Function
code
Parameter Name
Setting Range
Unit
Default
Commission
F4-10
DI filter time
0.000 to 1.000
s
0.010
F4-35
DI1 delay
0.0 to 3600.0
s
0.0
F4-36
DI2 delay
0.0 to 3600.0
s
0.0
F4-37
DI3 delay
0.0 to 3600.0
s
0.0
F4-38
DI active mode
selection 1
7-segment
0
0
0
0
0
00000
N.A
DI5 active mode:
☆
0: High level active
1: Low level active
DI4 active mode:
☆
0: High level active
1: Low level active
DI3 active mode:
☆
0: High level active
1: Low level active
DI 2 active mode:
☆
0: High level active
1: Low level active
DI 1 active mode:
☆
0: High level active
1: Low level active
☆
: ‘High level active’ means that, if a high level voltage is applied to DI terminal, the DI signal will be seen as active.
‘Low level active’ means that, if a low level voltage is applied to DI terminal, the DI signal will be seen as active.