Ver0.1
Page
11
of
53
Keys On Keypad
Key
Key Name
Function
Programming
Enter or exit Level I menu.
Confirm
Enter the menu interfaces level by level, and confirm the parameter setting.
Increment
Increase data or function code.
Decrement
Decrease data or function code.
Shift
Select the displayed parameters in turn in the stop or running state, and select the digit to be
modified when modifying parameters.
RUN
Start the AC drive in the keypad operation mode.
Stop/Reset
Stop the AC drive when it is in the running state and perform the reset operation when it is in
the faulty state. The functions of this key are restricted by
F7-02
.
Multifunction
Perform function switchover (such as quick switchover of command source or direction)
according to the setting of
F7-01
.
Function
code
Parameter Name
Setting Range
Unit
Default
Commission
F7-01
MF.K key function
selection
0: MF.K key disabled
1: Switchover from remote control (terminal or
communication) to keypad control
2: Switchover between forward rotation and
reverse rotation
3: Forward jog
4: Reverse jog
5: Individualized parameter display
N.A
0
F7-02
STOP/RESET key
function
0: STOP/RESET key enabled only in keypad
control
1: STOP/RESET key enabled in any
operation mode
N.A
1