Ver0.1
Page
26
of
53
CHAPTER 5 FUNCTION CODE TABLE
5.1
General Function Codes
Group F0: Standard
Function
code
Parameter Name
Setting Range
Unit
Default
Commission
F0-01
Motor 1 control mode
0: Sensorless vector control (SVC)
2: Voltage/Frequency control (V/F)
N.A
2
F0-02
Command source
selection
0 to 2
N.A
0
F0-03
Main frequency source
X selection
0 to 9
N.A
0
F0-04
Auxiliary frequency
source Y selection
The same as F0-03 (Main frequency source X
selection)
N.A
0
F0-05
Range of auxiliary
frequency Y for X and
Y operation
0: Relative to maximum frequency
1: Relative to main frequency X
N.A
0
F0-06
Range of auxiliary
frequency Y for X and
Y operation
0 to150
%
100
F0-07
Frequency source
selection
00 to 34
N.A
00
F0-08
Preset frequency
0.00 to maximum frequency (F0-10)
N.A
50.00
F0-09
Rotation direction
0: Same direction
1: Reverse direction
N.A
0
F0-10
Maximum frequency
50.00 to 600.00
Hz
50.00
F0-11
Source of frequency
upper limit
0 to 5
N.A
0
F0-12
Frequency upper limit
Frequency lower limit (F0-14) to maximum
frequency (F0-10)
Hz
50.00
F0-13
Frequency upper limit
offset
0.00 to maximum frequency (F0-10)
Hz
0.00
F0-14
Frequency lower limit
0.00 to frequency upper limit (F0-12)
Hz
0.00
F0-15
Carrier frequency
0.5 to 16.0
kHz
Model
dependent
F0-16
Carrier frequency
adjustment with
temperature
0: No
1: Yes
N.A
1
F0-17
Acceleration time 1
0.00 to 650.00(if F0-19=2)
0.0 to 6500.0 (if F0-19=1)
0 to 65000 (if F0-19=0)
s
Model
dependent
F0-18
Deceleration time 1
0.00 to 650.00(if F0-19=2)
0.0 to 6500.0 (if F0-19=1)
0 to 65000 (if F0-19=0)
s
Model
dependent
F0-19
Acceleration/Decelerat
ion time unit
0: 1
1: 0.1
2: 0.01
s
1
F0-21
Frequency offset of
auxiliary frequency
source for X and Y
operation
0.00 to maximum frequency (F0-10)
Hz
0.00
F0-22
Frequency reference
resolution
1: 0.1
2: 0.01
Hz
2
F0-23
Retentive of digital
setting frequency upon
power failure
0: Not retentive
1: Retentive
N.A
2
F0-25
Acceleration/Decelerat
ion time base
frequency
0: Maximum frequency (F0-10)
1: Frequency reference
2: 100
N.A
0
F0-26
Base frequency for
UP/DOWN modification
during running
0: Running frequency
1: Frequency reference
N.A
0
F0-27
Binding command source
to frequency source
0000 to 9999
N.A
0000