Group F4: Input Terminals
Function
code
Parameter Name
Setting Range
Unit
Default
Commission
F4-00
DI1 function selection
0 to 59
N.A
1
F4-01
DI2 function selection
0 to 59
N.A
4
F4-02
DI3 function selection
0 to 59
N.A
9
F4-03
DI4 function selection
0 to 59
N.A
12
F4-04
DI5 function selection
0 to 59
N.A
13
F4-05
DI6 function selection
0 to 59
N.A
0
F4-06
DI7 function selection
0 to 59
N.A
0
F4-07
DI8 function selection
0 to 59
N.A
0
F4-08
DI9 function selection
0 to 59
N.A
0
F4-09
DI10 function selection 0 to 59
N.A
0
F4-10
DI filter time
0.000 to 1.000
s
0.010
F4-11
Terminal wiring mode
selection
0: Two-wire mode 1
1: Two-wire mode 2
2: Three-wire mode 1
3: Three-wire mode 2
N.A
0
F4-12
Terminal UP/DOWN
rate
0.01 to 65.535
Hz/s
1.00
F4-13
AI curve 1 minimum
input
0.00 to F4-15
V
0.00
F4-14
Corresponding setting
of AI curve1 minimum
input
-100.0 to100.0
%
0.0
F4-15
AI curve 1 maximum
input
F4-13 to 10.00
V
10.00
F4-16
Corresponding setting
of AI curve1 maximum
input
-100.0 to 100.0
%
100.0
F4-17
AI1 filter time
0.00 to 10.00
s
0.10
F4-18
AI curve 2 minimum
input
0.00 to F4-20
V
0.00
F4-19
Corresponding setting
of AI curve2 minimum
input
-100.0 to 100.0
%
0.0
F4-20
AI curve 2 maximum
input
F4-18 to 10.00
V
10.00
F4-21
Corresponding setting
of AI curve2 maximum
input
-100.0 to 100.0
%
100.0
F4-22
AI2 filter time
0.00 to 10.00
s
0.10
F4-23
AI curve 3 minimum
input
0.00 to F4-25
V
0.00
F4-24
Corresponding setting
of AI curve3 minimum
input
-100.0 to100.0
%
0.0
F4-25
AI curve 3 maximum
input
F4-23 to 10.00
V
10.00
F4-26
Corresponding setting
of AI curve3 maximum
input
-100.0 to 100.0
%
100.0
F4-27
AI3 filter time
0.00 to10.00
s
0.10
F4-28
Pulse minimum input
0.00 to F4-30
kHz
0.00
F4-29
Corresponding setting
of pulse minimum
input
-100.0 to100.0
%
0.0
F4-30
Pulse maximum input
F4-28 to 50.00
kHz
50.00