7
2.3.2 External
Wastegate
2.4 MAP
sensor
1.
The MAP sensor MUST be installed with the hose fitting facing
down.
It is very important that the sensor be isolated from heat
sources, mounted away from all ignition and/or other potential RF
emitting sources, and protected against excessive vibration.
The MAP sensor has two 1/8” holes that can be used to secure the
sensor. Another viable option is to use double-sided mounting tape.
2. Locate a vacuum source on the intake manifold, after the throttle
body and connect it to the hose barb on the sensor. Use the
provided “T” and hose to make this connection if needed. To secure
the hose use tie-wraps or hose clamps.
3. With the engine idling, confirm that you do not have any air/vacuum
leaks.
2.5
Wideband Oxygen Sensor Setup
2.5.1
Oxygen Sensor Placement
Optimum bung placement will vary from application to application, but using
the guidelines below will ensure the longest sensor life with the most