13
5. Boost Cut by AFR
– This is a safety trigger to cut boost by a defined
AFR . There are two setup parameters to trigger this safely cut:
Start
Pressure (AFR Start Press)
and
AFR Cut. Start Pressure (AFR Start
Press)
is the minimum manifold absolute pressure where the safety cut
will become active.
AFR Cut
is the defined lean A/F that will trigger the
safety cut. When the
Boost Cut by AFR
is triggered, the SCG-1 will
display “O2 Cut” on the upper right hand corner. Default setting is a start
pressure of 4.9 PSI and 13 AFR.
Tuning Tip: Set the Start Pressure at the same pressure value as
Spring Pressure.
6. Boost Control ON/OFF –
When configured from the gauge, this setting
is accessed from the main screen. Press and HOLD both the left and
right interface buttons, this will disable/enable solenoid control. If there
are no other error codes on the status viewport of the screen, the SCG-1
will display “SC OFF”. In LM Programmer, use the Boost Control ON
checkbox to turn the solenoid control ON/OFF. Default setting is ON.
Logworks 3 & LM Programmer Software Package
4
The SCG-1 can be connected directly to your Windows computer to log and
analyze data with the Logworks software or to configure with LM
Programmer. The software is a free download on the Innovate Motorsports’
support section of the website.
4.1
Download and Install the Logworks 3 Software
1. Open your web browser and go to the following URL:
http://www.innovatemotorsports.com/support.php
2. The LogWorks 3 software download will be the very first thing on the
page under the heading Software, click the link to download the
software.
3. Double click on the Logworks 3 installer previously downloaded from the
support section of the Innovate Motorsports web site.
4. The installer will start, follow the prompts to install the software.
5. Once the software has been installed, the LogWorks software, LM
Programmer, manuals, and tools can then be located by navigating
through Start->Programs->LogWorks3.
4.2
LM Programmer
LM Programmer is used to configure settings on your SCG-1.
1. Connect the OUT port of the SCG-1 to the provided serial
programming cable. Connect the other end of the serial
programming cable to your computer. If your computer does not
have a serial port, you can purchase a USB to Serial adapter from
Innovate Motorsports (P/N 3733) or use any USB to serial adaptor