Manual IP 100 version 5.01
page 37
4.1.2 H.323 configuration
The parameters are set here, which are necessary for H.323, the voice over
IP protocol.
In the first section, you set the type of registration with the gatekeeper.
With “manual” the telephone automatically registers after turn on.
The IP address of the innovaphone PBX is used as the gateway address. The “Time
to live” parameter specifies how long the registration is valid. The alias is not
required by the innovaphone PBX. The H.323 ID corresponds to the MAC address
and thus to the last 12 digits of the equipment serial number. Fast start and
tunnelling are supported by the PBX and should always be turned on. Hold and
forward on the innovaphone PBX are compatible to the H.450 standard. DTMF
transmission is always active and the setting for this is thus meaningless.
Fig. 32 H.323 configuration
4.1.3 NAT configuration
The NAT configuration is irrelevant for the function of the innovaphone PBX.