Appendix III
Frequent questions and troubleshooting
Note: The solutions of common faults for reference are as follows. Please con-
tact sales agents for further support if needed.
•
Power does not turn off when pressing ON/OFF button.
•
Press and hold the key until the LED blinks, and then release the button to turn
off the splicer.
•
Few splices can be made with a fully charged battery pack.
•
Enable the power save option.
•
If degradation appears or the battery pack is stored for an extended period of
time, completely discharge it. And recharge the battery pack.
•
The battery pack has reached the end of its battery life. Change a new battery
pack.
•
The capacity decreases at excessive low temperature.
•
Error message appears on monitor.
•
Please refer to Appendix II.
•
High splice loss.
•
Clean the V-groove and fiber holders.
•
Replace the electrodes.
•
Please refer to Appendix I.
•
The splice loss varies according to the cleave angle, arc conditions and fiber
cleanliness.
•
Monitor suddenly turns off.
•
If the power save option is enabled, the monitor will turn off after an extended
period of splicer inactivity. Press any key to return to the normal state.
•
Splicer suddenly turns off.
•
If the power save option is enabled, the splicer will turn off after an extended
period of splicer inactivity.
•
Identify fiber error in AUTO mode.