Chapter 6
Heater Mode
34
Deleting heat mode
•
Select [Heater Mode] menu.
•
Select [Delete Heat Mode].
•
Select the heat mode to be deleted.
Note: The gray modes (20mm, 30mm) are the system preset initial heat modes
which cannot be deleted.
Heat mode parameters
Parameter
Description
Template
Set sleeve type. List of all heat modes are displayed. Selected mode will be
copied to a user-programmable area.
Name
Title for a heat mode.
Note
Title of the heat mode displayed in the upper right corner of the monitor
during splicing or heating process. Max number of character used is 5.
Heater
Control
Set the length of heat-shrink sleeve.
Long: protection sleeves over 30mm.
Short: 30mm protection sleeves or below.
Heat Temperature
Set heating temperature.
Heater Time
Set heating time from the beginning to the heating completed.
Cooling Time
Operating time of cooling fan.
Select the parameters to be edited.