InisBofin Insert Boiler Multi-fuel Stove
16
It MUST be checked if using the
external air provision that the
base plate if fitted so that the
front air grill on the front
bottom face of the stove are
covered by the base plate. If
these grills are open then the
base unit must be turned around
for external air mode. If
questions still remain please
contact Inis Stoves for further
details. The required blanking
plate can then be removed and the
coupling bolted on instead.
Stove preparation
The crate should be carefully
unscrewed to avoid possible damage
to the stove. Remove the plastic
packaging. Use a screw driver to
remove the screw holding the stove
in place. The wooden crating the
stove was shipped in can be cut up
for fuel in the stove. Take great
care to avoid damaging the facade
of the stove when removing the
stove from its shipping crate and
moving it into position.
To help with fitting of the
stove, the stove door and facade
and baffle assembly should be
removed. The door is removed by
opening the door and lifting up
approx. 20mm until the hinges are
clear and lift away. Take great
care not to drop the door as it is
quite heavy and the door glass can
easily be broken.
Façade removal:
The facade is removed (See Fig 8)
by unscrewing of the two screws on
both sides of the façade at floor
level, gently but firmly lift the
facade approx. 5mm by holding
towards the left and right sides
of the façade along the top to
avoid deforming the facade in the
middle. When the façade has been
lifted up, gently swing forward
from the top and dis-engage the
mounting tangs and lift away. Be
aware of the damper slider on the
left hand side and the riddling
mechanism on the right hand side
when pulling the façade out.
Remove the baffle assembly as
shown in the user manual and
remove the firebar and ash pan.
With the baffle assembly removed
the flue collar can be removed
prior to fitting of the stove.
Chimney
This stove is not suitable for a
shared flue arrangement. This
stove is only suitable for
installation into a fireplace with
an existing chimney. Chimneys must
satisfy standard EN 15287:2007. A
draught test should always be
performed prior to the fitting of
the stove to ensure that a proper
draft in the chimney is present
(Min 25Pa constant when warm.). A
chimney height of at least 4m from
the top of the stove and