10.13. Configure the inverter to work in self consumption mode
These inverters can work within a self consumption system. For this, you must configure the inverter for self
consumption system mode.
Access
Main Menu
>
Advanced settings
>
Self consumption
>
Mode
to select the self consumption mode.
There are different self consumption modes: No limitation (MPPT), Limited EMS manager and Self-limited CG
EM24.
No limitation (MPPT)
Self consumption mode without limits of injecting into the grid.
Limited EMS manager
Limited self consumption mode via the INGECON EMS Manager. For installations with
several inverters.
Self-limited CG EM24
Instantaneous self consumption mode limited by a wattmeter. For installations with a
single inverter.
10.14. Place the inverter in operating mode
To start the inverter in operating mode access
Main menu
>
Start/Stop
. This screen display's the inverter's current
status and enables, via a keypad
, changing the status. If the current status is stopped, press
to change it to
operating.
10.15. Place the inverter in stop mode
To place the inverter in stop mode access
Main menu
>
Start/Stop
. This screen display's the inverter's current
status and enables, via a keypad
, changing the status. If the current status is operating, press
to change it
to stopped.
10.16. See the daily power graph
2016-01-11
10:17
2016-01-11
10:17
The daily power graph displays the power generated throughout the current day. To see this graph, from the main
screen press
. Besides the daily power graph it lists the daily energy values (Ed), from the first connection of the
day to the time of consultation, total energy (Et) from the first inverter connection* and the instantaneous power (P).
* This historical meter returns to zero if reset to default settings.
10.17. See the energy graph for the last 24 days.
2016-01-11
10:17
2016-01-11
10:17
The energy graph of the last 24 days displays the energy generated throughout the last 24 days. To see this graph,
from the main screen press
. Besides the daily power graph of the last 24 days it lists the daily energy values
(Ed), from the first connection of the day to the time of consultation, total energy (Et) from the first inverter
connection* and the instantaneous power (P).
95
Display control
Ingeteam
ABE2011IQM01_C - Installation and Operation Manual
DE
EN
ES
FR
IT
PT
Summary of Contents for INGECON SUN 1Play TL M
Page 58: ...Anmerkungen Notes Notas Remarques Note Notas...
Page 108: ...Anmerkungen Notes Notas Remarques Note Notas...
Page 309: ...Anmerkungen Notes Notas Remarques Note Notas...
Page 310: ...Anmerkungen Notes Notas Remarques Note Notas...
Page 312: ...Ingeteam Power Technology S A www ingeteam com ABE2011IQM01_C 06 2016...