OPERATION
POWER OUTAGE RESTART OPTION
For customers that have
i
nterrupt
i
ons
i
n the
i
r
i
ncom
i
ng power supply
to the compressor and must ma
i
nta
i
n an un
i
nterrupted supply of
compressed a
i
r, the Power Outage Restart Opt
i
on allows an Intell
i
sys
compressor to restart automat
i
cally 10–120 seconds (ad
j
ustable) after
i
ncom
i
ng power
i
s restored
.
The Power Outage Restart Opt
i
on
i
s turned on by us
i
ng the customer
set rout
i
ne on the Intell
i
sys
controller
.
The restart t
i
me delay, wh
i
ch
i
s ad
j
ustable from 10–120 seconds, can also be ad
j
usted wh
i
le
i
n the
set rout
i
ne on the Intell
i
sys
controller
.
Any t
i
me power
i
s restored to
the compressor after a power
i
nterrupt
i
on and
i
f the compressor was
runn
i
ng when power was lost, a horn located on the s
i
de of the starter
box w
i
ll sound dur
i
ng the restart t
i
me delay (10–120 seconds), after
wh
i
ch the compressor w
i
ll automat
i
cally start
.
After start
i
ng, the
compressor w
i
ll return to the mode of operat
i
on that the compressor
was
i
n pr
i
or to the power
i
nterrupt
i
on
.
To operate
i
n the power outage restart mode, proceed w
i
th
follow
i
ng steps
:
1
.
Power up the un
i
t and wa
i
t for the Intell
i
sys
d
i
splay to read READY
TO START
.
2
.
Press the SET button once to enter the customer set po
i
nt
rout
i
ne
.
The Set Offl
i
ne A
i
r Pressure
i
nd
i
cator w
i
ll l
i
ght and the
d
i
splay w
i
ll show the set po
i
nt pressure
.
3
.
Press and release the SET button mult
i
ple t
i
mes unt
i
l the message
PWR OUT RSTR OFF
i
s d
i
splayed
.
4
.
Push the up or down arrows to change to the des
i
red cond
i
t
i
on
.
ON
i
n the d
i
splay
i
nd
i
cates Power Outage Restart
i
s turned on and OFF
i
n
the d
i
splay
i
nd
i
cates Power Outage Restart
i
s turned off
.
5
.
Once the select
i
on has been made, press SET button to put the
select
i
on
i
nto Intell
i
sys
memory
.
The d
i
splay w
i
ll flash tw
i
ce and the
message w
i
ll change to STR DELAY 10 Sec
i
f the opt
i
on was turned
on
.
Th
i
s message w
i
ll only d
i
splay
i
f the Power Outage Restart Opt
i
on
i
s turned on
.
6
.
Use the up or down arrows to select the des
i
red delay t
i
me (10–120
sec
.
)
.
7
.
Press SET and the d
i
splay w
i
ll flash tw
i
ce
i
nd
i
cat
i
ng the change has
been made
.
8
.
Push the DISPLAY SELECT BUTTON or wa
i
t 30 seconds for the
controller to automat
i
cally ex
i
t the set rout
i
ne
.
The d
i
splay returns to
READY TO START
.
Funct
i
on test
To test the operat
i
on of the Power Outage Restart Opt
i
on
:
1
.
Slowly open the ma
i
n
i
solat
i
on valve
.
2
.
Push the green START button on the Intell
i
sys d
i
splay to start the
compressor
.
3
.
The compressor w
i
ll load automat
i
cally
i
f there
i
s a suff
i
c
i
ent
demand for a
i
r
.
Allow the compressor to load
.
4
.
Open the ma
i
n d
i
sconnect to remove power from the compressor
.
5
.
Close the ma
i
n d
i
sconnect to reapply power to the compressor
.
The
horn w
i
ll sound and the Intell
i
sys
d
i
splay w
i
ll read START IN
___SEC
.
The d
i
splay w
i
ll count down the t
i
me unt
i
l the compressor
starts automat
i
cally and the horn stops
.
After start
i
ng, the compressor
w
i
ll automat
i
cally return to the same mode of operat
i
on as pr
i
or to the
power
i
nterrupt
i
on
.
Fault Analys
i
s
1
.
If the Intell
i
sys
d
i
splay
i
nd
i
cates the count down message and the
horn does not sound, check the w
i
r
i
ng of the horn
.
2
.
If the Intell
i
sys
d
i
splay does not
i
nd
i
cate the count down message,
the horn does not sound and the un
i
t does not restart automat
i
cally,
ver
i
fy that the Opt
i
on has been turned on
.
PORO OPTION – INTELLISYS
5
3
http:/air.ingersollrand.com
UP6 15, UP6 20, UP6 25, UP6 30
Summary of Contents for UP6 15HP
Page 2: ......
Page 52: ...PORO OPTION ELECTRO PNEUMATIC 50 UP6 15 UP6 20 UP6 25 UP6 30 http air ingersollrand com...
Page 58: ......
Page 108: ...OPCI N PORO ELECTRONEUM TICA 50 UP6 15 UP6 20 UP6 25 UP6 30 http air ingersollrand com...
Page 114: ......
Page 164: ...OPTION PORO ELECTRO PNEUMATIQUE 50 UP6 15 UP6 20 UP6 25 UP6 30 http air ingersollrand com...
Page 170: ......
Page 220: ...OP O PORO ELECTROPNEUM TICO 50 UP6 15 UP6 20 UP6 25 UP6 30 http air ingersollrand com...
Page 225: ......
Page 226: ......