background image

  
 
 
 
 
 
 

Operator Manual 

 

AIR COMPRESSOR

  

IMPORTANT  –  Please  make  certain  that  persons  who  are  to  use  this  equipment 

thoroughly  read  and  understand  these  instructions  and  any  additional  instructions 

provided  prior  to  operation. 

 

Record the model and serial numbers of your Generator below:

 

 

 

 

Model No._____________________ Serial No._______________________ 

Summary of Contents for PC121812

Page 1: ...rsons who are to use this equipment thoroughly read and understand these instructions and any additional instructions provided prior to operation Record the model and serial numbers of your Generator below Model No _____________________ Serial No _______________________ ...

Page 2: ...oducts certain procedures and specifications are subject to change without notice if you have any questions please contact Promate Service CONTENTS 1 Safety Precautions 3 2 1 Parts Description 4 2 Key Parts Diagram 6 3 Tool Compatibility Chart 7 4 Important Information 8 5 Product Features 8 6 Assembly 8 7 Operation 8 7 1 Before Starting 8 7 2 Starting the Compressor 9 7 3 Shutting Down the Compre...

Page 3: ...d the operator s manual To reduce the risk of injury read and understand operator s manual Wear safety glasses Operation of power tool can result in foreign objects being thrown into the eyes Wear respiratory protection Use of this tool can generate dust which may cause respiratory injury Wear hearing protection Noise from this product can contribute to hearing loss Wear gloves Wear gloves to redu...

Page 4: ...ch Keep proper footing and balance at all times Proper footing and balance enable better control of the tool in unexpected situations 8 Always secure your work Use clamps or a vise to hold work when practical It is safer than using your hand and frees both hands tooperate tool 9 Use safety equipment Always wear eye protection Dust mask non skid safety shoes hard hat or hearing protection must be u...

Page 5: ...he compressor is plugged into anoutlet that has the same configuration as theplug Do not use an adaptor with this compressor EXTENSION CORDS Keep the extensions cord clear of the working area Position the cord so that it will not get caught on lumber tools or other obstructions while you are working with a power tool Check the extension cords before each use Never use the tool with a damaged cord ...

Page 6: ...nd function of the controls and features Save this manual for future reference Model PC121812 Motor 220V 60Hz Universal Running Horsepower 1 8 HP Input Power 1700W Tank Size 12 Gallon 45 Liters Air Delivery 4 0 CFM 90 PSI Maximum Pressure 175 PSI 12 BAR Pump Design Oil free Power Cord SJT 16AWG 3C X1 8m Weight 30 kg 3 3 6 ...

Page 7: ...crewdriver Grease Gun Impact Wrench Ratchet Finish Nailer Spray Gun 30 70 PSI Framing Nailer Flooring Nailer Air Drill Sand Blaster Cut Off Tool Air Hammer Recommended Use Intermittent Use Not Recommended SAVE THESE INSTRUCTIONS Check the manufacturer s maximum pressure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating 7 ...

Page 8: ...ressure Gauge The gauge measures the pressure level of the air that is stored in the tank It cannot be adjusted by the operator and it does not indicate the pressure inside the line Tool Pressure Gauge The gauge measures the regulated outlet pressure Air Outlet Universal Coupler The outlet is connected to the 1 4 6 4 mm NPT air hose Tank Drain The tank drain is used to remove moisture from the air...

Page 9: ... accessories Fig F High pressure air could result in death or serious injury Never operate above maximum operating pressure of the spray gun or tool Hot compressor surfaces could result in serious injury Allow the compressor to cool before touching If the pump has been transported or turned upside down even partially allow the pump to sit in a normal upright position Fig A for approximately 10 min...

Page 10: ... when opening tank drain High pressure air could result in death or serious injury Shut off unit unplug and release air pressure prior to servicing High pressure air containing water condensation could result in minor or moderate injury Do not spray at any person 7 4 Draining the Tank 1 Set the power switch to the O OFF position 2 Turn air pressure regulator knob counter clockwise to set the outle...

Page 11: ... valve of any possible obstructions Daily Test for leakage Check all connections to see if tight A small leak of any part the tank hoses pipe connections or transfer tubes will reduce Monthly Storage Before storing the unit for a long period use an air blow gun to clean all the dust and debris from the compressor Disconnect and coil the power cord Pull the pressure relief valve to release all pres...

Page 12: ...e OFF position If the motor does not shut off unplug the air compressor If the power switch is defective replace it The compressor s capacity is not enough Check the air requirements of the accessory that is being used If it is higher than the CFM Cubic Feet per Minute and pressure supplied by the compressor page 7 a larger capacity air compressor is needed Most accessories are rated at 25 of actu...

Page 13: ...the customer fails to install maintain and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner s manual or if the product is used as rental equipment The Company will not pay for repairs or adjustments to the product or for any costs of labor performed without the Company s prior authorization Consumable parts such as battery spark plug...

Page 14: ...er 1 6 Control Panel 1 22 External Serrated Lock Washer φ5 2 7 Pressure Gauge 2 23 Cushion Pad 3 8 Pressure Regulator 1 24 Air Filter 1 9 Safety Valve 1 25 Flat Washers φ8 3 10 Tee Fitting 1 26 Check Valve 1 11 Quick Coupler 2 27 Hexagon Socket Bolt M8x35 3 12 Screw M5x14 2 28 Hose 1 13 Crimping Board 1 29 Elbow Fitting 1 14 Power Cord 1 30 Upper Cover 1 15 Handle Cover 1 31 Screw ST3 9x16F 10 16 ...