CALIBRATION
The dryer is supplied factory set and therefore requires no further
calibration.
ENGINEERING DATA
Compressor
UP6 15 - 30
Maximum
operating
pressure psig (bar)
125
(8.62)
150
(10.34)
200
(13.79)
Factory
set
reload
pressure psig (bar)
110
(7.58)
135
(9.31)
185
(12.76)
Model
UP6 20
UP6 25
UP6 30
UP6 15
Pressure Dew Point ( F)
(see note 3. below)
38
Base–Mounted Dryer
Package Weight (lb)
1411
1451
1537
120 Gallon Tank Dryer
Package Weight (lb)
1735
1775
1861
240 Gallon Tank Dryer
Package Weight (lb)
2004
2044
2130
Electrical Supply
(+/– 10%) (AC)
(see note 2. below)
115V / 1ph / 60Hz
L.R.A. Current (Amps)
45.0
48.8
48.8
F.L.A. Current (Amps)
9.6
12.3
12.3
Total Installed Power (kW)
0.96
1367
1691
1960
45.0
9.6
0.96
1.19
1.19
Electrical Protection Class
(Std.)
NEMA 1 (IP20)
Refrigerant Type
134a
Notes:
1. Electrical data refers to dryer only.
2. The dryer requires a separate power supply from the compressor
drive.
3.
Rated at:
Working Pressure (psig)
100
Inlet Air Temperature ( F)
100
Ambient Temperature ( F)
100
Relative Humidity (%)
100
Notes on the use of the Schrader non–return valve.
ATTENTION
1. This unit is equipped with refrigerant as for quantity and kind clearly
shown in operating manual and with identification label.
2. Any ordinary test and / or refrigerant recharge by means of
connections can take place only after refrigerant evacuation. The
evacuation must be proportional to dimensions and length of the
connections used. The use of the valve can be justified only when the
dryer is not in working order.
3. During the unit guarantee period, the Schrader valve can be used by
authorized staff only, otherwise any damage caused by a wrong
refrigerant recharge will invalidate warranty.
39
DRYER
OPTION
http:/air.ingersollrand.com
UP6 15, UP6 20, UP6 25, UP6 30
Summary of Contents for UP6 15HP
Page 2: ......
Page 52: ...PORO OPTION ELECTRO PNEUMATIC 50 UP6 15 UP6 20 UP6 25 UP6 30 http air ingersollrand com...
Page 58: ......
Page 108: ...OPCI N PORO ELECTRONEUM TICA 50 UP6 15 UP6 20 UP6 25 UP6 30 http air ingersollrand com...
Page 114: ......
Page 164: ...OPTION PORO ELECTRO PNEUMATIQUE 50 UP6 15 UP6 20 UP6 25 UP6 30 http air ingersollrand com...
Page 170: ......
Page 220: ...OP O PORO ELECTROPNEUM TICO 50 UP6 15 UP6 20 UP6 25 UP6 30 http air ingersollrand com...
Page 225: ......
Page 226: ......