OPERATING INSTRUCTIONS
25
HP935, VHP750, MHP825, XHP750, XP1060
OPERATING CONTROLS AND INSTRUMENTS
The operating controls and instruments are arranged
on the control panel as shown above. A description of
each panel device is as follows:
1.
Panel Light: Illuminates the instrument
control panel controlled by Switch 14.
2.
High Compressor Temp: Fault indicator
lamp. Indicates shutdown due to high
compressor temperature.
3.
Low Radiator Coolant Level: Alarm indicator
lamp. Indicates engine coolant needs service.
4.
Low Engine Oil Pressure: Fault indicator
lamp. Indicates shutdown due to low engine oil
pressure.
5.
Restricted Air Filter: Alarm indicator lamp.
Indicates engine/compressor air inlet filters
need service.
6.
High Engine Coolant Temp: Fault indicator
lamp. Indicates shutdown due to high engine
water temperature.
7.
Restricted IQ Air Filters: Fault indicator
lamp. Indicates shutdown due to high pressure
in ”IQ” air filters (if equipped).
8.
Low Fuel Level: Fault indicator lamp.
Indicates shutdown due to low fuel level. Lamp
blinks at low fuel warning.
9.
Compressor Malfunction: Fault indicator
lamp. Indicates shutdown due to compressor
system fault. Refer to Fault Code List.
10.
Low Battery Voltage: Alarm indicator lamp.
Indicates battery or charging system requires
service.
11.
Engine Malfunction: Engine Fault code.
Refer to service card or engine manual for
codes and service requirements.
12.
Malfunction Code (4 Digit): Compressor or
engine fault. Refer to manual for list of codes
and service requirements.
13.
Inlet Heater
/ Wait to Start Lamp: Indicates
engine manifold pre heater is energized. Wait
until lamp extinguishes before engaging
starter.
14.
Panel Light Switch: Controls panel lamp # 1.
15.
Service Air Switch: Momentary contact
switch. Allows engine to warm up at low
compressor pressure.
16.
ON/OFF Start Switch: Main Power Control
Switch.
17.
Heater Switch: ON/OFF Power Switch for
regulation and IQ heaters. Prevents freeze up
in cold weather.
18.
Hourmeter: Indicates machine operating
hours.
19.
E–STOP: Emergency Stop Push Button (ESA
units only). Push to stop, turn to release.
20.
Discharge Air Pressure Gage: Indicates
pressure in receiver tank, normally from 0
psi(kPa) to the rated pressure of the machine.
21.
Engine Tachometer: Indicates engine speed
in RPM from 0 when stopped to full speed.
22.
Fuel Level Gage: Indicate fuel level in tank.
23.
Engine Water Temp Gage
24.
Compressor Oil Temp Gage
25.
Engine Oil Pressure Gage
26.
Battery Voltage Gage