MAINTENANCE
38
HP935, VHP750, MHP825, XHP750, XP1060
LUBRICATION
The engine is initially supplied with engine oil sufficient for a nominal
period of operation (for more information, consult The Engine
Manufacturer’s Manual).
CAUTION: Always check the oil levels before a new machine is put into
service.
If, for any reason, the unit has been drained, it must be re–filled with
new oil before it is put into operation.
ENGINE LUBRICATING OIL
The engine oil should be changed at the engine manufacturer’s
recommended intervals. Refer to the SERVICE / MAINTENANCE
CHART.
ENGINE LUBRICATING OIL SPECIFICATION
Refer to the Engine Manufacturer’s Manual or Lubrication
Specification list.
ENGINE OIL FILTER ELEMENT
The engine oil filter element should be changed at the engine
manufacturer’s recommended intervals. Refer to the SERVICE /
MAINTENANCE CHART..
COMPRESSOR LUBRICATING OIL
Refer to the SERVICE/MAINTENANCE CHART in this section for
service intervals.
NOTE: If the machine has been operating under adverse conditions,
or has suffered long shutdown periods, then more frequent service
intervals will be required.
WARNING: DO NOT, under any circumstances, remove any drain
plugs or the oil filler plug from the compressor lubricating and
cooling system without first making sure that the machine is
stopped and the system has been completely relieved of all air
pressure (refer to STOPPING THE UNIT in the OPERATING
INSTRUCTIONS section of this manual).
Completely drain the receiver/separator system including the piping
and oil cooler by removing the drain plug(s) and collecting the used oil
in a suitable container.
Replace the drain plug(s) ensuring that each one is secure.
NOTE: If the oil is drained immediately after the machine has been
running, then most of the sediment will be in suspension and will
therefore drain more readily.
CAUTION: Some oil mixtures are incompatible and result in the
formation of varnishes, shellacs or lacquers which may be insoluble.
NOTE: Always specify INGERSOLL–RAND Pro–Tec
TM
oil for use
at all ambient temperatures above –23
C.
RUNNING GEAR WHEEL BEARINGS
Wheel bearings should be packed with grease every 6 months. The
type of grease used should conform to specification MIL–G–10924.