OPERATING INSTRUCTIONS
26
HP935, VHP750, MHP825, XHP750, XP1060
Wedge Diagnostic Display Codes
If the
fault indicator lamp is illuminated, refer to the
Alert/Shutdown list below.
If the
fault indicator lamp is illuminated, refer to the
Engine diagnostic list below.
ALERT/SHUTDOWN CONDITIONS
ALERT
SHUTDOWN
CODE
LIGHT
BLINKS
CODE
LIGHT
STEADY
DELAY
(sec)
Engine Speed < Min. RPM
1
CPRSR
Malfunction.
30
Engine Speed > Max. RPM
2
CPRSR
Malfunction.
30
Engine Crank Time Exceeded
3
CPRSR
Malfunction.
0
*Engine Oil Temperature
> 252 deg. F
5
CPRSR
Malfunction.
*Intake Manifold Temperature
>180 deg. F
6
CPRSR
Malfunction.
*Water In Fuel – CUMMINS
8
CPRSR
Malfunction.
Engine Not Responding To
Throttle command
10
CPRSR
Malfunction.
Too Many Crank Attempts
During Autostart
11
CPRSR
Malfunction.
0
Engine Shut Itself Down:
reason unknown
29
CPRSR
Malfunction.
0
Low AE Oil Pressure
31
CPRSR
Malfunction.
20
Disch. Temp (RT2)
Sensor Fault
32
CPRSR
Malfunction.
10
Sep. Tank Pressure (PT1)
Sensor Fault
33
CPRSR
Malfunction.
Seperator Tank Pressure >20
PSI During Start Attempt
(Engine Will Not Crank)
34
CPRSR
Malfunction.
0
Machine Over Pressure
35
CPRSR
Malfunction.
1
Safety Valve Open
36
CPRSR
Malfunction.
2
*CAN derived data