EP20-XXXXX-XXX-XXX (en)
Page 19 of 44
Fieldbus Communication Option A Cards:
These are available for aftermarket installation only and should be installed in the VFD option A slot. Please note this is only
available for ordinary applications.
Part Number
Description
130B1200
Profibus DP VI MCA 101, coated
130B1202
DeviceNet MCA 104, coated
130B1205
CAN Open MCA 105, coated
130B1235
PROFINET MCA 120, coated
130B1219
EtherNet IP MCA 121, coated
130B1296
Modbus TCP MCA 122, coated
130B5646
EtherCAT MCA 124, coated
RS485
61
68
69
+
_
6.10. User defined readout
Parameters 030, 031, and 032 are available to modify the “User Defined Readout” that will display in the top left corner of
the main menu screen. By default, these values are set to scale motor frequency to actual pump rpm. To update the “User
Defined Readout”, refer to the following parameter descriptions.
1.
Select the unit to be displayed on LCP from option given in parameter 030.
2.
Minimum value is set to zero in parameter 031.
3.
Maximum value is set for parameter 032 based on maximum motor frequency (92 Hz) set in parameter 414 and calcu-
lated as below.
Pump unit (Maximum) =
Motor sync. RPM (1500) X Maximum motor frequency (92 Hz)
x unit conversion factor (X)
“Motor Frequency (50 Hz) X GB ratio (12.7)”
Pump Unit (parameter 030)
* Unit conversion factor (X)
RPM
1
Gallons per Minute
0.65
Liters per Minute
2.46
NOTE:
Adjust unit conversion factor for the selected unit given in parameter 030 to calculate maximum value for parameter
032 per the above formula.
* Unit conversion factor values are approximate and depend on back pressure.