Ingersoll-Rand 251A1 Operation And Maintenance Manual Download Page 3

3

PLACING PUMP IN SERVICE

 LUBRICATION 

Ingersoll–Rand No. 50

Ingersoll–Rand No. 80
Water Pump Grease

Never use ordinary cup grease as it emulsifies in water.
Automotive water pump grease is not satisfactory as it is
made for use with hot water and is too hard for use in cold
water.

Always use an air line lubricator with these pumps.
We recommend the following Portable Air Line Lubricator:

For USA – 16LUB16C
For International – No. 16LUB16C

Before starting the pump, unless the air line lubricator is
used, detach the air hose and place 15 – 20 drops of
Ingersoll–Rand No. 50 Oil into the air inlet.  Unscrew the
Oil Chamber Plug and fill the oil chamber with oil.

After each eight hours of operation, or as experience
indicates, refill the oil chamber with oil.

Weekly, or as experience indicates, inject Ingersoll–Rand
No. 80 Grease into the three Grease Fittings. Inject 1 to 2 cc
into the Grease Fitting located in the Backhead and the
Fitting nearest the discharge in the Housing.  The other
Grease Fitting in the Housing leads to the grease chamber
on the automatic lubricator.  Pump grease into this Fitting
until grease starts to seep from the Grease Level Valve.

MAIN LINES 3 TIMES
AIR TOOL INLET SIZE

TO
AIR
SYSTEM

TO
AIR
TOOL

LUBRICATOR

REGULATOR

FILTER

BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE

DRAIN REGULARLY

COMPRESSOR

(Dwg. TPD905–1)

 OPERATION 

Always use an Exhaust Hose and be certain the free end of
the Hose is kept well above the surface of the liquid.
Do not allow the pump to operate at free speed (not
submerged) for long periods of time.  The frictional heat
generated will damage the composition sealing members.
Prevent dirt from entering the pump. When pumping from a
ditch or natural sump, set the pump on a board or flat stone
or suspend it a few inches from the bottom of the sump.
Arranging a wire screen around the inlet or setting the
pump in a wire basket is also recommended.
If the inlet becomes clogged, stop the motor and lift the
pump from the liquid.  Liquid flowing through the
discharge line will usually flush the obstruction from the
inlet.
If the pump is stopped while pumping dirty liquids, gravel
washed back through the pump by the liquid in the
discharge line may sprag the impeller and prevent the
motor from starting when the air is turned on.  If the gravel
cannot be dislodged by jarring or striking the pump with a
wooden block; make sure that the air is turned off, remove
the air line from the pump, remove the Inlet and rotate the
Impeller by hand.
Be certain the Governor Valve slides freely in the Governor
Valve Bushing. A sticking Governor Valve is the most
common cause of erratic motor speed. A loose, sloppy fit
resulting from a badly worn Valve or Bushing produces the
same effect.

  HOW TO ORDER A SUMP PUMP  

Size of Opening Pump will Pass Through

Model

in.

mm

Pump Housing Material

251A1

9–1/2 x 11–3/4

241 x 298

Iron

251A3

9–1/2 x 11–3/4

241 x 298

Iron

Summary of Contents for 251A1

Page 1: ...Always turn off the air supply and disconnect the air supply hose before installing removing or adjusting any accessory on this pump or before performing any maintenance on this pump Do not use damage...

Page 2: ...Pumps are assembled at the factory with 0 010 clearance When due to wear this clearance has increased to 0 032 1 32 remove enough Impeller Cover Shims to obtain the original 0 010 clearance White is 0...

Page 3: ...ays use an Exhaust Hose and be certain the free end of the Hose is kept well above the surface of the liquid Do not allow the pump to operate at free speed not submerged for long periods of time The f...

Page 4: ...taller d poser ou ajuster toute accessoire sur cette pompe ou d entreprendre une op ration d entretien quelconque sur la pompe Ne pas utiliser des flexibles ou des raccords endommag s effiloch s ou d...

Page 5: ...ct entre l impulseur et le couvercle d impulseur 52 1 Les pompes sont assembl es en usine pour donner un jeu de 0 010 Lorsqu cause de l usure ce jeu atteint 0 032 le jeu d origine doit tre r tabli en...

Page 6: ...LIGNE SECONDAIRE AU MOINS 2 FOIS LA DIMEN SION DE L ADMISSION D AIR DE L OUTIL VIDANGER R GULI REMENT COMPRESSEUR Plan TPD905 1 FONCTIONNEMENT Utiliser toujours un flexible d chappement et s assurer q...

Page 7: ...de instalar desmontar o ajustar cualquier accesorio de esta bomba o antes de realizar cualquier operaci n de mantenimiento de la misma No utilice mangueras de aire y racores da ados desgastados o dete...

Page 8: ...g 0 25 mm Cuando debido al uso la holgura haya aumentado hasta 0 032 pulg 1 32 pulg 0 81 mm saque suficientes calzos de la cubierta del impulsor para conseguir la holgura original de 0 010 pulg 0 25 m...

Page 9: ...TAMA O DE ENTRADA DE HERRAMIENTA NEUM TICA PURGAR PERI DICAMENTE COMPRESOR Esq TPD905 1 FUNCIONAMIENTO Utilice siempre siempre una manguera de escape y aseg rese de que el extremo abierto de la mangu...

Page 10: ...a de alimenta o de ar antes de instalar remover ou ajustar qualquer acess rio nesta ferramenta ou antes de executar qualquer servi o de manuten o nesta ferramenta N o use mangueiras de ar ou adaptador...

Page 11: ...a de f brica como sendo 0 010 Quando devido ao desgaste esta dist ncia tiver aumentado cerca de 1 32 um ajuste pode ser feito ao remover algumas Juntas da Cobertura do Impulsor para obter 0 010 de dis...

Page 12: ...DA FERRAMENTA PNEUM TICA PARA SISTEMA DE AR PARA FERRAMENTA PNEUM TICA LUBRIFICADOR REGULADOR FILTRO LINHA RAMIFICADA 2 VEZES O TAMANHO DA ENTRADA DA FERRAMENTA PNEUM TICA DRENE REGULARMENTE COMPRESS...

Page 13: ...MAINTENANCE SECTION 13 Dwg TPA271 1...

Page 14: ...mpeller Cover Cap Screw 4 PB25 146 12 Dead Handle P250 48 50 3 8 Lock Washer 4 D02 321 13 Cylinder Dowel P250 98 51 Inlet P25 148B 14 Rear End Plate P251 12 52 Impeller Cover P251 144 15 Housing Gaske...

Page 15: ...5 135 66 Grease Chamber Cap Seal R2C 103 Fire Hose Adapter one end 2 1 2 pipe thread to fit Perforated Bottom Plate special requires pump discharge other end 3 1 16 O D the use of No P25 140 PB250 147...

Page 16: ...Motor Housing in the vise vertically Unscrew the Housing Nut 16 and carefully remove the Backhead 36 5 While grasping the Governor Assembly 17 in one hand gently tap on the impeller end of the Arbor...

Page 17: ...ssembly of the Sump Pump 1 Place the Arbor Bearing Spring 58 Arbor Bearing Spacer 25 and the Front Arbor Bearings 44 on the Arbor 47 2 Install the Front Arbor Bearing Seat 57 against the Front Bearing...

Page 18: ...ION If lubrication does not result in satisfactory operation disassemble the pump inspect and clean all parts Erratic speed Sticking Governor Valve Replace Governor Valve and or Governor Valve Bushing...

Page 19: ...19 NOTES...

Reviews: