![Ingersoll-Rand 251A1 Operation And Maintenance Manual Download Page 18](http://html1.mh-extra.com/html/ingersoll-rand/251a1/251a1_operation-and-maintenance-manual_2060410018.webp)
18
MAINTENANCE SECTION
TROUBLESHOOTING GUIDE
Trouble
Probable Cause
Solution
Low power or low free speed
Dirty Air Strainer Screen
Using a clean, suitable, cleaning solution in a well–
ventilated area, clean the Air Strainer Screen.
Allow to air dry.
Worn or broken Vanes
Replace complete set of Vanes.
Worn or broken Cylinder
Examine Cylinder and replace it if it is worn or bro-
ken or if bore is scored or wavy.
Improper lubrication or dirt
build–up in the motor
Lubricate the pump as instructed in
LUBRICATION. If lubrication does not result in
satisfactory operation, disassemble the pump,
inspect and clean all parts.
Erratic speed
Sticking Governor Valve
Replace Governor Valve and/or Governor Valve
Bushing.
Rough operation
Worn or broken Rear Rotor Bear-
ing or Front Rotor Bearing
Examine each Bearing. Replace if worn or
damaged.
Worn Rotor Key
Replace the Key. Check the Rotor Shaft and Rotor
for keyslot wear and replace if necessary.
Scoring of End Plates and
Cylinder
Improper assembly
Make certain that all motor parts are properly
aligned prior to clamping the motor assembly.
Arbor Packing misalignment
Remove the Backhead. Rotate the motor by hand to
align the Seal.
SAVE THESE INSTRUCTIONS. DO NOT DESTROY.