Ingersoll-Rand 251A1 Operation And Maintenance Manual Download Page 1

Refer All Communications to the Nearest
Ingersoll–Rand Office or Distributor.

 Ingersoll–Rand Company 1996

Printed in U.S.A.

03524360

Form P5931
Edition 12
March, 1996

OPERATION AND MAINTENANCE MANUAL

251A1 AND 251A3 SUMP PUMPS

Models 251A1 and 251A3 Sump Pumps are particularly recommended for contractors and
maintenance crews where lightweight, compactness, and low air consumption are prime
factors.
Ingersoll–Rand is not responsible for customer modification of pumps for applications on
which Ingersoll–Rand was not consulted.

IMPORTANT SAFETY INFORMATION ENCLOSED.

READ THIS MANUAL BEFORE OPERATING PUMP.

IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PLACE THE INFORMATION

IN THIS MANUAL INTO THE HANDS OF THE OPERATOR.

FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY.

PLACING PUMPS IN SERVICE

Always operate, inspect and maintain this tool in
accordance with American National Standards
Institute Safety Code for Portable Air Tools
(ANSI B186.1).

For safety, top performance, and maximum
durability of parts, operate this pump at 90 psig 
(6.2 bar/620 kPa) maximum air pressure at the inlet
with 1” (25 mm) inside diameter air supply hose.

Always turn off the air supply and disconnect the
air supply hose before installing, removing or
adjusting any accessory on this pump, or before
performing any maintenance on this pump.

Do not use damaged, frayed or deteriorated air
hoses and fittings.

Be sure all hoses and fittings are the correct size
and are tightly secured. See Dwg. TPD905–1 for a
typical piping arrangement.

Always use clean, dry air at 90 psig maximum air
pressure.  Dust, corrosive fumes and/or excessive
moisture can ruin the motor of an air pump.

Do not lubricate pumps with flammable or volatile
liquids such as kerosene, diesel or jet fuel.

Do not remove any labels. Replace any damaged
label.

USING THE PUMP

Always wear eye protection when operating or
performing maintenance on this pump.

Always wear hearing protection when operating
this pump.

Use accessories recommended by Ingersoll–Rand.

Do not start or operate this pump unless it is
submerged.

This pump is not designed for working in explosive
atmospheres.

This pump is not insulated against electric shock.

The use of other than genuine Ingersoll–Rand replacement parts may result in safety hazards, decreased pump
performance, and increased maintenance, and may invalidate all warranties.

Repairs should be made only by authorized trained personnel.  Consult your nearest Ingersoll–Rand Authorized
Servicenter.

  F

E

P

TPD1456

Summary of Contents for 251A1

Page 1: ...Always turn off the air supply and disconnect the air supply hose before installing removing or adjusting any accessory on this pump or before performing any maintenance on this pump Do not use damage...

Page 2: ...Pumps are assembled at the factory with 0 010 clearance When due to wear this clearance has increased to 0 032 1 32 remove enough Impeller Cover Shims to obtain the original 0 010 clearance White is 0...

Page 3: ...ays use an Exhaust Hose and be certain the free end of the Hose is kept well above the surface of the liquid Do not allow the pump to operate at free speed not submerged for long periods of time The f...

Page 4: ...taller d poser ou ajuster toute accessoire sur cette pompe ou d entreprendre une op ration d entretien quelconque sur la pompe Ne pas utiliser des flexibles ou des raccords endommag s effiloch s ou d...

Page 5: ...ct entre l impulseur et le couvercle d impulseur 52 1 Les pompes sont assembl es en usine pour donner un jeu de 0 010 Lorsqu cause de l usure ce jeu atteint 0 032 le jeu d origine doit tre r tabli en...

Page 6: ...LIGNE SECONDAIRE AU MOINS 2 FOIS LA DIMEN SION DE L ADMISSION D AIR DE L OUTIL VIDANGER R GULI REMENT COMPRESSEUR Plan TPD905 1 FONCTIONNEMENT Utiliser toujours un flexible d chappement et s assurer q...

Page 7: ...de instalar desmontar o ajustar cualquier accesorio de esta bomba o antes de realizar cualquier operaci n de mantenimiento de la misma No utilice mangueras de aire y racores da ados desgastados o dete...

Page 8: ...g 0 25 mm Cuando debido al uso la holgura haya aumentado hasta 0 032 pulg 1 32 pulg 0 81 mm saque suficientes calzos de la cubierta del impulsor para conseguir la holgura original de 0 010 pulg 0 25 m...

Page 9: ...TAMA O DE ENTRADA DE HERRAMIENTA NEUM TICA PURGAR PERI DICAMENTE COMPRESOR Esq TPD905 1 FUNCIONAMIENTO Utilice siempre siempre una manguera de escape y aseg rese de que el extremo abierto de la mangu...

Page 10: ...a de alimenta o de ar antes de instalar remover ou ajustar qualquer acess rio nesta ferramenta ou antes de executar qualquer servi o de manuten o nesta ferramenta N o use mangueiras de ar ou adaptador...

Page 11: ...a de f brica como sendo 0 010 Quando devido ao desgaste esta dist ncia tiver aumentado cerca de 1 32 um ajuste pode ser feito ao remover algumas Juntas da Cobertura do Impulsor para obter 0 010 de dis...

Page 12: ...DA FERRAMENTA PNEUM TICA PARA SISTEMA DE AR PARA FERRAMENTA PNEUM TICA LUBRIFICADOR REGULADOR FILTRO LINHA RAMIFICADA 2 VEZES O TAMANHO DA ENTRADA DA FERRAMENTA PNEUM TICA DRENE REGULARMENTE COMPRESS...

Page 13: ...MAINTENANCE SECTION 13 Dwg TPA271 1...

Page 14: ...mpeller Cover Cap Screw 4 PB25 146 12 Dead Handle P250 48 50 3 8 Lock Washer 4 D02 321 13 Cylinder Dowel P250 98 51 Inlet P25 148B 14 Rear End Plate P251 12 52 Impeller Cover P251 144 15 Housing Gaske...

Page 15: ...5 135 66 Grease Chamber Cap Seal R2C 103 Fire Hose Adapter one end 2 1 2 pipe thread to fit Perforated Bottom Plate special requires pump discharge other end 3 1 16 O D the use of No P25 140 PB250 147...

Page 16: ...Motor Housing in the vise vertically Unscrew the Housing Nut 16 and carefully remove the Backhead 36 5 While grasping the Governor Assembly 17 in one hand gently tap on the impeller end of the Arbor...

Page 17: ...ssembly of the Sump Pump 1 Place the Arbor Bearing Spring 58 Arbor Bearing Spacer 25 and the Front Arbor Bearings 44 on the Arbor 47 2 Install the Front Arbor Bearing Seat 57 against the Front Bearing...

Page 18: ...ION If lubrication does not result in satisfactory operation disassemble the pump inspect and clean all parts Erratic speed Sticking Governor Valve Replace Governor Valve and or Governor Valve Bushing...

Page 19: ...19 NOTES...

Reviews: