CD1-k – Installation Guide
Chapter 5 - Appendix
2 – ADJUSTMENT TO VARIOIUS RESOLVER TYPES
For the use of other resolvers than those mounted on MAVILOR motors in their standard version, see following
wiring diagram of the
X1
connector as well as the manufacturer's diagram:
X1
3
11
10
2
4
5
1
S1
S3
S4
S2
R1
R2
Sin
Cos
Ref
For the use of
resolvers
with
transformation ratios
out of the range 0.3 to 0.5, the adjustment must be factory
set.
NOTE
When using resolvers with a number of pole pairs N > 1, all speed values displayed in the amplifier are equal to N
times the motor rotation speed.
3 - USE OF THE "AOK" OUTPUT
The "AOK" output MUST be used on a potential free relay in order to allow the connection of the power supply
(see
The correct amplifier operation requires this connection logic. Switching on the power supply before
initializing by means of the 24 VDC auxiliary supply will hinder the operation. It will then be necessary to
proceed according to the instructions contained in this manual.
24V
AOK
(1)
Power relay
remote control
Power
ON
Power
OFF
Power
relay
(1)
CAUTION
! Imax = 100 mA (see AOK output specifications)