Compliance with the standards:
CE
certification.
360° shield connection, equipotentiality according
to the wiring rules.
CD1-400/70 and 90 A with mains filtre F-400-
70/90.
Conformity with the standards:
UL
listing
"360°" shield; equipotentiality according to the
wiring rules.
EMC standards:
- immunity: EN 61000.4-2-3-4-5
- conducted and radiated disturbances: EN 55011, Group 1,
C3 category
Electrical standards for industrial machines:
- EN 60204-1: insulator 1500 Vac / 1 mn
leakage current > 30 mA (EMI filters).
CD1-k series have been “
c
UL
us
” listed according to UL508C
and UL840 regarding the insulator.
This product was evaluated to:
- the Third Edition of UL508C, the UL Standard for Power
Conversion Equipment, dated May 2002 for the UL Listing
(USL),
- the CSA Standard for Industrial Control Equipment, C22.2
N° 14-95, dated August 1995 for the Canadian UL Listing
(CNL) except for CD1-k-400/70 and 90 drives.
Temperature
- storage: -20° C to +70° C
- operation: +5° C to +40° C
From 40° C, the rated currents must be reduced of
3 % per additional Celsius degree
Max. temperature: 50° C
Altitude 1000
m
Moisture
< 50% at 40° C and < 90% at 20° C: EN 60204-1 standard
Condensation prohibited (storage and operation)
Cooling
Forced air (fan integrated in the CD1-k amplifier)
Check for free ventilation and no upper or lower obstruction of
the air admissions
Mounting position
Vertical
Environment
Open chassis to be mounted in a housing protecting the
amplifier from conducting dust and condensation (pollution
degree 2 environment)
Mounting location
Closed cabinet without any conducting and/or corroding
agents and according to the environment conditions
requirements
Condensation prohibited
Weight
CD1-k-230/I: about 1 kg
CD1-k-400/1.8 to 7.2 A: about 1.5 kg
CD1-k-400/14: about 3 kg
CD1-k-400/30 and 45: about 4.8 kg
CD1-k-400/70 and 90: about 5.3 kg