6
Chapter 1 - General description
CD1-K- Installation Guide
2.2 - REFERENCE TO THE STANDARDS: "CE" CERTIFICATION
Series CD1-k amplifiers have been approved with regard to their conformity with the Electromagnetic Compatibility
standards concerning the power servos referenced in the EN 61800-3:2004 standard "Electrical variable speed
power servo systems":
- EN 55011, group 1, C3 category, regarding radiated radioelectric disturbances,
- EN 61000.4-2-3-4-5 regarding immunity.
Standard to be applied to the electrical equipment of industrial machines: EN 60204-1.
These items have been "CE" marked since year 2000.
2.3 - REFERENCE TO THE STANDARDS: "UL" LISTING
CD1-k series have been «
c
UL
us
» listed according to UL508C and UL840 regarding the insulator.
This product was evaluated to:
- the Third Edition of UL508C, the UL Standard for Power Conversion Equipment, dated May 2002 for the UL
Listing (USL),
- the CSA Standard for Industrial Control Equipment, C22.2 N° 14-95, dated August 1995 for the Canadian UL
Listing (CNL) except for CD1-k-400/70 and 90 drives.
Providing that the manual is specifying that the end user has to provide an isolated power supply, for 24 VDC
auxiliary input protected by a 4 A UL Listed fuse, the power board is considered within a limited voltage/current
circuit per section 31.4 of UL508C. Therefore, spaces on the power board are not required to be evaluated per
section 31.2 of UL508C and were evaluated according to UL 840.
Per UL 840 (Second Edition, dated May 20, 1993) requirements, spaces are limited to 2.5 mm assuming pollution
degree 2 environment.
Ground connection is fixed in the frame of the device by a rivet, Avibulb masse, BN10-5168. The connector
complies with standard dimensions given in table 6.2 of UL 310, the standard for Electrical Quick connect
terminals.
3 - OTHER DOCUMENTS REQUIRED FOR THE COMMISSIONING
CANopen communication protocol for CD1-k amplifiers
CD1-a/CD1-k SinCos track feedback" application note regarding the use of motors equipped with
"SinCos tracks" position sensors.
CD1-a/CD1-k absolute encoders feedback" application note regarding the use of absolute single-turn,
multi-turn or linear encoders using the ENDAT or HIPERFACE Communication protocols.