26
CD1-k – Installation Guide
Chapter 4 – Connections
Chapter 4 - Connections
1 - CONNECTION DIAGRAMS
1.1 - CD1-k-230/I AMPLIFIER
(For the UL compliant connection, see
2
10
11
3
5
4
12
13
3
1
2
TC
TC
S3
S1
S2
S4
R1
R2
X1
4
X8
X9
10
9
8
7
6
5
4
3
2
1
**
**
230V
400V
dp *
6
5
4
X9
24V
CD1-k-230/I
+24 Vdc
230 Vac R
230 Vac S
24 V
X2
X6, X7
1
2
3
4
5
6
7
8
9
9
10
1
3
4
7
15
8
6
+
-
* CD1-k-230/I : 100 ohms / 100 W
24 Vdc
3A
AC
230 Vac
-
+
+/-15%
AOK
(1)
AOK
(1)
AOK/
Motor temp.
Motor temp.
Resolver
signal
Resolver
reference
GND
GND
GND
RESOLVER
GND
Motor U phase
Motor V phase
Motor W phase
DC+
DC-
230 Vac L3
230 Vac L2
230 Vac L1
230 Vac
three-phase
Braking resistor
Braking resistor
230 Vac
single-phase
Power relay
remote control
Power
relay
Power
relay
Mains
230 Vac
Braking
resistor
Mains
3x400V
MOTOR
OR
Power
ON
Power
OFF
Power
relay
INHIBIT
FC+
FC-
Index
Reference
Capture
Speed limitation
CAN-L
CAN-GND
CAN-H
Motor brake+
Motor brake-
Motor
brake
24 Vdc/1.5A
isolated
**
Circuit breaker type D
I1s = 10 x In
In = 10 A
(1) CAUTION ! Imax = 100 mA (See AOK output specifications).
GND
Phase 1
Phase 2
Phase 3
Note: The 24 V and power supplies protection, on source side, must be made by the user.