Infinova V6812IR-H0 Series User Manual Download Page 8

25 

4.3.7 IGMP Settings 

 

Figure 4-15 IGMP Settings 

V6812IR-H0 series camera supports multicast function. In the IGMP interface, 
users can select the stream type and set the state, multicast IP address and RTP 
port.  
 

4.3.8 SIP Settings 

 

Figure 4-16 SIP Settings 

26 

SIP Server

: to configure SIP server for device; 

SIP Server IP: the IP address of SIP server; 
Port: the port number of SIP server; 
Server ID: the ID of SIP server; 
Device ID: the device ID used for registration with SIP server; 
Alarm ID: the ID registered for device alarm;   
Register Interval: the interval for re-registration of device in seconds;   
Heat Beat Interval: the interval to send heat beat information by the device in 
seconds;  
After configuration completed, click Save and the device sends a registration 
request to the server.   
 

Position Information

: the mounting information or instruction for device. 

Longitude: the longitude of mounting position, as precise to two places of 
decimal; 
Latitude: the latitude of mounting position, as precise to two places of decimal. 
 

27 

4.4 Camera Settings 

Click “Camera” in the navigation bar to enter the interface shown as below: 

 

Figure 4-17 Basic Settings   

 

4.4.1 Basic Settings 

You can set the following parameters:   
Flicker frequency: 50Hz or 60Hz.   
CVBS: it automatically changes with the flicker frequency.   
Enable or disable backlight compensation or digital WDR.   
Exposure set, scene, AGC, auto aperture, shutter speed and manual AGC can 
also be set in this interface. 
Exposure Set: Manual, Scene and Shutter Priority available. In Scene mode, 
indoor or outdoor can be selected and AGC can be set (maximum 64X); if set to 

28 

Manual mode, shutter speed can be set from 

1/30s to 1/8000s

 and manual AGC 

can be set to 

1X to 64X

, yet the scene and AGC are nonadjustable; if set to 

Shutter Priority mode, the shutter speed and AGC can be set.   
Auto aperture: to enable or disable auto iris.   
Contrast Enhance: 1~6 levels match with 6 kinds of Gamma curve separately. If 
it is set to Auto, the system will adjust automatically. 
AE target: set AE target level. It can adjust video brightness via AE target setup. 
 

4.4.2 Effect Settings 

In the Effect Settings interface, users can adjust the brightness, sharpness, hue, 
contrast, saturation and 3D denoise in two ways: General or Mode, as shown in 
the figure below:   

 

Figure 4-18 Effect Set - General   

Summary of Contents for V6812IR-H0 Series

Page 1: ...while there is no guarantee that interference will not occur in a certain particular installation situation Read this manual carefully before installation This manual should be saved for future use Important Safety Instructions and Warnings Electronic devices must be kept away from water fire or high magnetic radiation Clean with a dry cloth Provide adequate ventilation Unplug the power supply whe...

Page 2: ...ng 1 3 System Requirement Configuration of the computer to display image and control the camera CPU Intel Pentium 4 2 4 GHz or above RAM 512 MB or greater Network Port 100M Ethernet port Operating System Microsoft Windows 7 Microsoft Windows XP IE Browser Version Microsoft Internet Explorer 6 0 or above 3 1 4 Product Model This manual is for the following models V6812IR H0165SA HD Megapixel IR IP ...

Page 3: ...g the unit and contact your local dealer 7 This camera features AGC circuit so when the camera is applied under low illumination sensitivity will enhance automatically making images look rough which is normal 8 The camera power supply is 12VDC Be sure of the terminal correct 9 Firstly perform network settings after login Gateway IP address should be set to the IP address of the gateway that the de...

Page 4: ... is 192 168 1 254 For normal access correctly set local IP parameters before system login Do log in the system with the default super user for the first time to run the software The default Super User is admin password admin Note Do change the password in time to secure your system 2 Install and run Control After a successful login the prompt of security warning will pop up to remind the user to i...

Page 5: ... supports local recording Click the recording button to start recording when the button changes to click it to stop recording During local recording REC appears on the video screen Click the button 15 to enter the recording storage path Default C InfiPlayerAX Video Users can set the snap shooting and recording storage path in the video settings interface Indicate that the motion detection and priv...

Page 6: ...e process Power off will make update fail even damage the original program or unable to update again After update successfully it needs to reboot the system There is time prompt in the web page during reboot After reboot it will skip to new web page to run new program Note Available only for the super user Factory Settings V6812IR H0 series camera provides online reset function which greatly facil...

Page 7: ...ngs then alarm triggered images FTP upload can be achieved 4 3 3 SMTP Settings Figure 4 11 SMTP Settings 23 User needs to set mail server recipient etc in SMTP settings interface Server IP Set mail server address From Set sender s mail address To Mail address of recipient CC Mail address of the person copy to Authentication Enable or disable authentication function This function should be set acco...

Page 8: ...ck Camera in the navigation bar to enter the interface shown as below Figure 4 17 Basic Settings 4 4 1 Basic Settings You can set the following parameters Flicker frequency 50Hz or 60Hz CVBS it automatically changes with the flicker frequency Enable or disable backlight compensation or digital WDR Exposure set scene AGC auto aperture shutter speed and manual AGC can also be set in this interface E...

Page 9: ...ue gain 31 4 4 4 IR Settings Figure 4 21 IR mode set IR illuminators working mode Options Day Night Auto turn on or off as per ambient light Switch time in auto mode the response time for day night switch Power set the adjusting mode of illuminators power consumption Options Auto Manual In auto mode adjust illuminators brightness as per ambient light In manual mode adjust the brightness by moving ...

Page 10: ...pies less bandwidth When the setting goes with constant bit rate then the image is transmitted under a constant bandwidth 34 Bit Rate You have to set the upper limit of bit rate if vbr is selected the stream size will be fixed if cbr is selected and the stream size is defined in the Bit Rate For major stream the bit rate can be 256 10000kbps for minor stream the bit rate can be 256 2000Kbps Image ...

Page 11: ...nction If there is certain location within the surveillance area where operators are not allowed to see and thus Privacy Mask can be applied System covers and shields the sensitive area via Privacy Mask setting to avoid operators observing certain sensitive locations on monitor Note do turn on privacy mask function in Live View interface before privacy mask setting Figure 4 25 Privacy Mask Setting...

Page 12: ...ing the set period of each Sunday if Everyday is selected alarm will be enabled during the set period of everyday and then set the time period Enter the start time and end time in the 24 hour format The end time must be larger than the start time 4 7 Account Settings The default super user is admin password admin Super user can add delete common user and change the password of common users Super u...

Page 13: ... rounds or more Make sure the filter can be well closed Step 3 Close the magnetic ring filter Notice The magnetic ring filter should be installed no more than 50 mm away from the power output connector As shown in Figure 3 the cable length from A to B should be 50mm at most Figure 1 Closed magnetic ring filter Figure 2 Open magnetic ring filter Figure 3 Power cable with magnetic ring filter 48 APP...

Page 14: ...burial thus to ensure the electric connection to the metal tube In case it s difficult to thread the cable through the tube all the way it s acceptable to use tube threaded cables only at both ends of the transmission line yet the length in burial should be no less than 15 meters The cable sheath and the tube should be connected to the lightning proof grounding device Additional high power lightni...

Reviews: