APPENDIX III LIGHTNING & SURGE PROTECTION 

The product adopts multi-level anti-lightning and anti-surge technology integrated with gas discharge tube, 
power resistor and TVS tube. The powerful lightning and surge protection barrier effectively avoids 
product damage caused by various pulse signals with power below 4kV, including instantaneous lightning, 
surge and static. However, for complicated outdoor environment, refer to instruction below for lightning 
and surge protection: 

 

The product features with dedicated earth wire, which must be firmly grounded. As for surveillance 
sites beyond the effective protection scope, it’s necessary to erect independent lightening rods to 
protect the security devices. It’s recommended to separate the lightning rod from the mounting pole, 
placing the rod on an independent pole, as shown in the figure below. If the product has to be installed 
on the same pole or pedestal for lightning rod, there should be strict insulation between the video cable 
BNC terminal, power cable, control cable and the standing pole of the lightning rod. 

 

For suburb and rural areas, it’s recommended to adopt direct burial for the transmission cables. 
Overhead wiring is prohibited, because it’s more likely to encounter lightning strike. Use shielded 
cables or thread the cables through metal tubes for burial, thus to ensure the electric connection to the 
metal tube. In case it’s difficult to thread the cable through the tube all the way, it’s acceptable to use 
tube-threaded cables only at both ends of the transmission line, yet the length in burial should be no 
less than 15 meters. The cable sheath and the tube should be connected to the lightning -proof 
grounding device. 

 

Additional high-power lightning-proof equipment and lightning rods should be installed for strong 
thunderstorm or high induced voltage areas (such as high-voltage substation). 

 

The lightning protection and grounding for outdoor devices and wires should be designed in line with 
the actual protection requirement, national standards and industrial standards. 

 

The system should perform equipotential grounding by streaming, shielding, clamping and earthing. 
The grounding device must meet anti-interference and electric safety requirements. There should be no 
short-circuiting or hybrid junction between the device and the strong grid. Make sure there’s a reliable 
grounding system, with grounding resistance below 4

 (below 10

 for high soil resistivity regions). 

The cross-sectional area of the earthing conductor should be no less than 25mm².

 

Lightning rod

Front device 
for surveillance 
system

Separated layout for the lightning 

rod and the standing pole

LPZO

B

LPZO

A

Mounting 

pole for 

front device

30°

30°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Infinova 

51 Stouts Lane, 

Monmouth Junction, NJ 08852, U.S.A. 

Tel: 1-888-685-2002 (USA only) 

1-732-355-9100 

Fax: 1-732-355-9101 

[email protected] 

 

 

 

 

 

 

 

 

 

 

 

 

 

V1.5 1407

 

Summary of Contents for V6812IR-H0 Series

Page 1: ...while there is no guarantee that interference will not occur in a certain particular installation situation Read this manual carefully before installation This manual should be saved for future use Important Safety Instructions and Warnings Electronic devices must be kept away from water fire or high magnetic radiation Clean with a dry cloth Provide adequate ventilation Unplug the power supply whe...

Page 2: ...ng 1 3 System Requirement Configuration of the computer to display image and control the camera CPU Intel Pentium 4 2 4 GHz or above RAM 512 MB or greater Network Port 100M Ethernet port Operating System Microsoft Windows 7 Microsoft Windows XP IE Browser Version Microsoft Internet Explorer 6 0 or above 3 1 4 Product Model This manual is for the following models V6812IR H0165SA HD Megapixel IR IP ...

Page 3: ...g the unit and contact your local dealer 7 This camera features AGC circuit so when the camera is applied under low illumination sensitivity will enhance automatically making images look rough which is normal 8 The camera power supply is 12VDC Be sure of the terminal correct 9 Firstly perform network settings after login Gateway IP address should be set to the IP address of the gateway that the de...

Page 4: ... is 192 168 1 254 For normal access correctly set local IP parameters before system login Do log in the system with the default super user for the first time to run the software The default Super User is admin password admin Note Do change the password in time to secure your system 2 Install and run Control After a successful login the prompt of security warning will pop up to remind the user to i...

Page 5: ... supports local recording Click the recording button to start recording when the button changes to click it to stop recording During local recording REC appears on the video screen Click the button 15 to enter the recording storage path Default C InfiPlayerAX Video Users can set the snap shooting and recording storage path in the video settings interface Indicate that the motion detection and priv...

Page 6: ...e process Power off will make update fail even damage the original program or unable to update again After update successfully it needs to reboot the system There is time prompt in the web page during reboot After reboot it will skip to new web page to run new program Note Available only for the super user Factory Settings V6812IR H0 series camera provides online reset function which greatly facil...

Page 7: ...ngs then alarm triggered images FTP upload can be achieved 4 3 3 SMTP Settings Figure 4 11 SMTP Settings 23 User needs to set mail server recipient etc in SMTP settings interface Server IP Set mail server address From Set sender s mail address To Mail address of recipient CC Mail address of the person copy to Authentication Enable or disable authentication function This function should be set acco...

Page 8: ...ck Camera in the navigation bar to enter the interface shown as below Figure 4 17 Basic Settings 4 4 1 Basic Settings You can set the following parameters Flicker frequency 50Hz or 60Hz CVBS it automatically changes with the flicker frequency Enable or disable backlight compensation or digital WDR Exposure set scene AGC auto aperture shutter speed and manual AGC can also be set in this interface E...

Page 9: ...ue gain 31 4 4 4 IR Settings Figure 4 21 IR mode set IR illuminators working mode Options Day Night Auto turn on or off as per ambient light Switch time in auto mode the response time for day night switch Power set the adjusting mode of illuminators power consumption Options Auto Manual In auto mode adjust illuminators brightness as per ambient light In manual mode adjust the brightness by moving ...

Page 10: ...pies less bandwidth When the setting goes with constant bit rate then the image is transmitted under a constant bandwidth 34 Bit Rate You have to set the upper limit of bit rate if vbr is selected the stream size will be fixed if cbr is selected and the stream size is defined in the Bit Rate For major stream the bit rate can be 256 10000kbps for minor stream the bit rate can be 256 2000Kbps Image ...

Page 11: ...nction If there is certain location within the surveillance area where operators are not allowed to see and thus Privacy Mask can be applied System covers and shields the sensitive area via Privacy Mask setting to avoid operators observing certain sensitive locations on monitor Note do turn on privacy mask function in Live View interface before privacy mask setting Figure 4 25 Privacy Mask Setting...

Page 12: ...ing the set period of each Sunday if Everyday is selected alarm will be enabled during the set period of everyday and then set the time period Enter the start time and end time in the 24 hour format The end time must be larger than the start time 4 7 Account Settings The default super user is admin password admin Super user can add delete common user and change the password of common users Super u...

Page 13: ... rounds or more Make sure the filter can be well closed Step 3 Close the magnetic ring filter Notice The magnetic ring filter should be installed no more than 50 mm away from the power output connector As shown in Figure 3 the cable length from A to B should be 50mm at most Figure 1 Closed magnetic ring filter Figure 2 Open magnetic ring filter Figure 3 Power cable with magnetic ring filter 48 APP...

Page 14: ...burial thus to ensure the electric connection to the metal tube In case it s difficult to thread the cable through the tube all the way it s acceptable to use tube threaded cables only at both ends of the transmission line yet the length in burial should be no less than 15 meters The cable sheath and the tube should be connected to the lightning proof grounding device Additional high power lightni...

Reviews: