Maximum Frame 

Rate  

30fps@1280

×

960 30fps@1280

×

720 

Data Rate 

Variable bit rate; 
Constant bit rate: 256Kbps~10000Kbps (Major 
stream); 256Kbps~2000Kbps (Minor stream) 

Motion Detection 

Up to 4 areas 

Privacy Mask 

Up to 4 masks 

ROI

 

 

Local Recording 

Available 

Upgrade Online 

Available 

Password 

Protection 

Available 

Network Port 

One RJ45 10/100M self-adaptive Ethernet port 

Analog Video 

Output

 

Available via BNC port

 

Applicable 

Protocols 

IPv4, TCP, UDP, IGMP, DHCP, FTP, SNMP (V3), 
SMTP, NTP, RTP, RTSP, RTCP, HTTP, HTTPS, TSL, 
SSL, 802.1X, Qos, PPPoE, DNS, ARP, ICMP 

Power Supply 

12VDC 

Power 

Consumption 

5W 

Operating 

Temperature 

14°F~122°F (-10°C~+50°C) 

Storage 

Temperature

 

-4° F ~ 140° F (-20° C ~ 60° C)

 

Operating 

Humidity 

0%-90% RH (non-condensing) 

Dimensions (H×Ø) 

3.34"×4.71" (84.7mm×119.5mm) 

Box Dimensions 

(L×W×H) 

6.65 "×6.65 "×5.79" (169mm×169mm×147mm) 

Unit Weight 

1.43lbs. (0.65kg) 

Shipping Weight 

1.83lbs. (0.83kg) 

 

1.6 Precautions 

1.

 

Do not drop the camera or subject it to strong knock. 

2.

 

Do not point the camera lens toward the sun or other strong light. 

3.

 

Do not install the camera in environment with temperature beyond the 
acceptable range (from -10°C to 50°C). 

4.

 

Never let liquid of any kind flow into this unit. 

5.

 

Do not directly touch the CMOS element. If it is necessary to clean the 

element, use a soft cloth moistened with alcohol to wipe off the dust. 

6.

 

If any abnormality occurs, make sure to unplug the unit and contact your 
local dealer. 

7.

 

This camera features AGC circuit, so when the camera is applied under 
low illumination, sensitivity will enhance automatically, making images 
look rough, which is normal. 

8.

 

The camera power supply is 12VDC. Be sure of the +/- terminal correct.   

9.

 

Firstly perform network settings after login. Gateway IP address should be 
set to the IP address of the gateway that the device connects to. 

10.

 

The IP address is not allowed to conflict with that of other devices; 
otherwise, you cannot visit the camera.   

CHAPTER II INSTALLATION   

Step 1: Prepare mounting holes 

Attach the enclosed mounting schematic label on the desired position of wall 
or ceiling; drill holes according to the label’s instruction (4 mounting holes 
and 1 cable hole).   

 

Figure 2-1   

Step 2: Install camera base 

Unscrew the base and take it off. Install the base to the ceiling via the 4 
mounting holes.   

   

 

Figure 2-2 

 

Step 3: Pre-fasten minidome camera

 

Install tightening ring, chuck ring and dome module to the base. Keep tightening 
ring loose, so that the dome module can turn freely.

 

Tightening ring

Chuck ring

Dome module

 

Figure 2-3 

Step 4: Adjust dome module 

1.

 

Turn the dome module to make it point to surveillance area. The 
camera features X, Y, Z 3-axis adjustment. It allows 0°~360° panning 
adjustment, 

-75°~75°

 tilting adjustment and 0°~360° rotating 

adjustment. 

2.

 

Adjust the lens according to the schematic label; make sure 
photosensitive resistance lies at the bottom; then fasten 

tightening ring.

   

 

Photosensitive resistance

Keep the arrowhead up 

when mounting.

 

Figure 2-4 

 

Summary of Contents for V6812IR-H0 Series

Page 1: ...while there is no guarantee that interference will not occur in a certain particular installation situation Read this manual carefully before installation This manual should be saved for future use Important Safety Instructions and Warnings Electronic devices must be kept away from water fire or high magnetic radiation Clean with a dry cloth Provide adequate ventilation Unplug the power supply whe...

Page 2: ...ng 1 3 System Requirement Configuration of the computer to display image and control the camera CPU Intel Pentium 4 2 4 GHz or above RAM 512 MB or greater Network Port 100M Ethernet port Operating System Microsoft Windows 7 Microsoft Windows XP IE Browser Version Microsoft Internet Explorer 6 0 or above 3 1 4 Product Model This manual is for the following models V6812IR H0165SA HD Megapixel IR IP ...

Page 3: ...g the unit and contact your local dealer 7 This camera features AGC circuit so when the camera is applied under low illumination sensitivity will enhance automatically making images look rough which is normal 8 The camera power supply is 12VDC Be sure of the terminal correct 9 Firstly perform network settings after login Gateway IP address should be set to the IP address of the gateway that the de...

Page 4: ... is 192 168 1 254 For normal access correctly set local IP parameters before system login Do log in the system with the default super user for the first time to run the software The default Super User is admin password admin Note Do change the password in time to secure your system 2 Install and run Control After a successful login the prompt of security warning will pop up to remind the user to i...

Page 5: ... supports local recording Click the recording button to start recording when the button changes to click it to stop recording During local recording REC appears on the video screen Click the button 15 to enter the recording storage path Default C InfiPlayerAX Video Users can set the snap shooting and recording storage path in the video settings interface Indicate that the motion detection and priv...

Page 6: ...e process Power off will make update fail even damage the original program or unable to update again After update successfully it needs to reboot the system There is time prompt in the web page during reboot After reboot it will skip to new web page to run new program Note Available only for the super user Factory Settings V6812IR H0 series camera provides online reset function which greatly facil...

Page 7: ...ngs then alarm triggered images FTP upload can be achieved 4 3 3 SMTP Settings Figure 4 11 SMTP Settings 23 User needs to set mail server recipient etc in SMTP settings interface Server IP Set mail server address From Set sender s mail address To Mail address of recipient CC Mail address of the person copy to Authentication Enable or disable authentication function This function should be set acco...

Page 8: ...ck Camera in the navigation bar to enter the interface shown as below Figure 4 17 Basic Settings 4 4 1 Basic Settings You can set the following parameters Flicker frequency 50Hz or 60Hz CVBS it automatically changes with the flicker frequency Enable or disable backlight compensation or digital WDR Exposure set scene AGC auto aperture shutter speed and manual AGC can also be set in this interface E...

Page 9: ...ue gain 31 4 4 4 IR Settings Figure 4 21 IR mode set IR illuminators working mode Options Day Night Auto turn on or off as per ambient light Switch time in auto mode the response time for day night switch Power set the adjusting mode of illuminators power consumption Options Auto Manual In auto mode adjust illuminators brightness as per ambient light In manual mode adjust the brightness by moving ...

Page 10: ...pies less bandwidth When the setting goes with constant bit rate then the image is transmitted under a constant bandwidth 34 Bit Rate You have to set the upper limit of bit rate if vbr is selected the stream size will be fixed if cbr is selected and the stream size is defined in the Bit Rate For major stream the bit rate can be 256 10000kbps for minor stream the bit rate can be 256 2000Kbps Image ...

Page 11: ...nction If there is certain location within the surveillance area where operators are not allowed to see and thus Privacy Mask can be applied System covers and shields the sensitive area via Privacy Mask setting to avoid operators observing certain sensitive locations on monitor Note do turn on privacy mask function in Live View interface before privacy mask setting Figure 4 25 Privacy Mask Setting...

Page 12: ...ing the set period of each Sunday if Everyday is selected alarm will be enabled during the set period of everyday and then set the time period Enter the start time and end time in the 24 hour format The end time must be larger than the start time 4 7 Account Settings The default super user is admin password admin Super user can add delete common user and change the password of common users Super u...

Page 13: ... rounds or more Make sure the filter can be well closed Step 3 Close the magnetic ring filter Notice The magnetic ring filter should be installed no more than 50 mm away from the power output connector As shown in Figure 3 the cable length from A to B should be 50mm at most Figure 1 Closed magnetic ring filter Figure 2 Open magnetic ring filter Figure 3 Power cable with magnetic ring filter 48 APP...

Page 14: ...burial thus to ensure the electric connection to the metal tube In case it s difficult to thread the cable through the tube all the way it s acceptable to use tube threaded cables only at both ends of the transmission line yet the length in burial should be no less than 15 meters The cable sheath and the tube should be connected to the lightning proof grounding device Additional high power lightni...

Reviews: